Worked example
Example: Damaged gas well, skin 4. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas permeability | 12.000 mD |
| Net pay thickness | 25.000 ft |
| Average reservoir pressure | 1,800.0 psi |
| Flowing bottom-hole pressure | 1,100.0 psi |
| Reservoir temperature | 175.00 °F |
| Gas viscosity at the mean pressure | 0.016000 cP |
| Gas compressibility factor at the mean pressure | 0.85000 - |
| Drainage radius | 1,490.0 ft |
| Wellbore radius | 0.35400 ft |
| Skin factor | 4.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas rate (standard) | 4,277.9 Mscf/d |
| Pressure at which to evaluate μ and Z | 1,491.6 psi |
| Open-flow rate (p_wf = 0) | 6,827.7 Mscf/d |
Open this example in the calculator and change any input.
Formula
\(Q_g = \frac{\pi kh\,T_n(\bar p_r^2 - p_{wf}^2)}{p_nT\mu_gZ\left[\ln(r_e/r_w) - 0.75 + s\right]}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | Gas permeability | m² |
| \(h\) | Net pay thickness | m |
| \(\bar p_r\) | Average reservoir pressure | Pa |
| \(p_{wf}\) | Flowing bottom-hole pressure | Pa |
| \(T\) | Reservoir temperature | K |
| \(\mu_g\) | Gas viscosity at the mean pressure | Pa·s |
| \(Z\) | Gas compressibility factor at the mean pressure | - |
| \(r_e\) | Drainage radius | m |
| \(r_w\) | Wellbore radius | m |
| \(s\) | Skin factor | - |
| \(Q_g\) | Gas rate (standard) | Nm³/s |
| \(\bar p\) | Pressure at which to evaluate μ and Z | Pa |
| \(Q_{max}\) | Open-flow rate (p_wf = 0) | Nm³/s |
Method and standards
Real-gas radial flow at pseudo-steady state.
Where it is used
- Gas well forecasts.
- Checking test-derived deliverability against reservoir data.
Common mistakes
- Using μ and Z at reservoir pressure instead of the mean.
- Using gauge pressures.
Assumptions and limits
- Laminar flow; μZ nearly constant.
Questions and answers
Why pressure squared?
Gas density rises with pressure; integrating Darcy's law with ρ ∝ p/(Z) gives a p² driving force when μZ is nearly constant.
Which Z and μ should I use?
Those at the mean pressure √((p̄² + p_wf²)/2) shown in the results.
What do the defaults represent?
An illustrative case: Damaged gas well, skin 4. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 6, eqs. 6-139 and 6-150 (pressure-squared approximation with skin)