Worked example
Example: Tight gas well, n near 0.9. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Average reservoir pressure (shut-in) | 2,800.0 psi |
| Bottom-hole pressure, test 1 | 2,500.0 psi |
| Gas rate, test 1 | 850.00 Mscf/d |
| Bottom-hole pressure, test 2 | 1,900.0 psi |
| Gas rate, test 2 | 1,900.0 Mscf/d |
| Bottom-hole pressure for the forecast | 1,200.0 psi |
Applying the formula below gives:
| Result | Value |
|---|---|
| Back-pressure exponent | 0.82207 |
| Performance coefficient (Mscf/d per psi^2n) | 0.006783 |
| Absolute open flow (back-pressure) | 3,155.4 Mscf/d |
| Rate at the forecast pressure (back-pressure) | 2,670.5 Mscf/d |
| Absolute open flow (LIT quadratic) | 3,011.9 Mscf/d |
| Rate at the forecast pressure (LIT) | 2,598.5 Mscf/d |
Open this example in the calculator and change any input.
Formula
\(n = \frac{\log(Q_2/Q_1)}{\log\frac{\bar p_r^2 - p_{wf2}^2}{\bar p_r^2 - p_{wf1}^2}}, \quad Q = C(\bar p_r^2 - p_{wf}^2)^n, \quad \bar p_r^2 - p_{wf}^2 = aQ + bQ^2\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\bar p_r\) | Average reservoir pressure (shut-in) | Pa |
| \(p_{wf1}\) | Bottom-hole pressure, test 1 | Pa |
| \(Q_1\) | Gas rate, test 1 | Nm³/s |
| \(p_{wf2}\) | Bottom-hole pressure, test 2 | Pa |
| \(Q_2\) | Gas rate, test 2 | Nm³/s |
| \(p_{wf}\) | Bottom-hole pressure for the forecast | Pa |
| \(n\) | Back-pressure exponent | - |
| \(C\) | Performance coefficient (Mscf/d per psi^2n) | - |
| \(AOF\) | Absolute open flow (back-pressure) | Nm³/s |
| \(Q_g\) | Rate at the forecast pressure (back-pressure) | Nm³/s |
| \(AOF_{LIT}\) | Absolute open flow (LIT quadratic) | Nm³/s |
| \(Q_{LIT}\) | Rate at the forecast pressure (LIT) | Nm³/s |
Method and standards
Back-pressure and LIT deliverability.
Where it is used
- Gas well testing and allowables.
- Compressor and tubing studies.
Common mistakes
- Using flow periods that had not stabilised.
- Using gauge pressures.
Assumptions and limits
- Stabilised (pseudo-steady) flow periods; same reservoir pressure.
Questions and answers
What does n tell me?
n = 1 means purely laminar (Darcy) flow; n = 0.5 means fully turbulent flow near the wellbore. Most wells lie between 0.6 and 0.9.
Why can the two methods differ?
The back-pressure line is straight on log-log axes and over-predicts open flow if turbulence grows with rate; the LIT quadratic captures that growth.
What do the defaults represent?
An illustrative case: Tight gas well, n near 0.9. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ahmed, Reservoir Engineering Handbook, 5th ed. (Gulf Professional Publishing, 2019), ch. 8, eqs. 8-22, 8-23 and 8-29 and Example 8-2 (Rawlins and Schellhardt)