FireCADCalc

Condensation Inside Tubes: Shah, Boyko–Kruzhilin, Breber, Stratified

Local condensing coefficient inside a tube by Shah, Boyko–Kruzhilin and Breber et al. (shear-controlled) and the stratified-flow Nusselt form, with j* and X_tt.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Steam condensing at 1 atm, x = 0.5, 20 mm tube, 100 kg/(m2 s)Refrigerant at 15 bar, x = 0.8, 8 mm tube, 300 kg/(m2 s)

Accepted: 1 to 5,000 kg/(m²·s)
Accepted: 3 to 100 mm
Accepted: 0.1 to 99 %
Accepted: 0.1 to 100 K
Accepted: 1 to 30,000 kPa
Accepted: 100 to 30,000 kPa
Accepted: 50 to 2,000 kg/m³
Accepted: 0.01 to 500 kg/m³
Accepted: 0.001 to 100 mPa·s
Accepted: 1E-4 to 1 mPa·s
Accepted: 0.01 to 1 W/(m·K)
Accepted: 0.5 to 10 kJ/(kg·K)
Accepted: 10 to 3,000 kJ/kg

Results

Shah (1979) with the Dittus–Boelter h_LO at saturation properties; Breber et al. use h_LO (φ_LO²)^0.45 (exponent 0.5 removes their ~15 % margin). j* above 1.5 with X_tt below 1 indicates annular (shear-controlled) flow; j* below 0.5 stratified (gravity-controlled).

Reynolds number, total flow as liquid20,000
Liquid Prandtl number2.4800
All-liquid coefficient (Dittus–Boelter)855.67W/(m²·K)
Dimensionless vapour velocity (regime map)3.1686
Lockhart–Martinelli parameter0.095145
Shah coefficient4,271.1W/(m²·K)
Boyko–Kruzhilin coefficient2,889.1W/(m²·K)
Two-phase multiplier (Müller-Steinhagen–Heck)11.280
Breber et al. coefficient, exponent 0.452,545.9W/(m²·K)
Void fraction (Chisholm slip)96.661%
Stratified-flow coefficient2,407.2W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steam condensing at 1 atm, x = 0.5, 20 mm tube, 100 kg/(m2 s). The inputs, in the units selected above:

InputValue
Total mass flux100.00 kg/(m²·s)
Tube inside diameter20.000 mm
Vapour quality50.000 %
Saturation minus wall temperature10.000 K
Pressure101.33 kPa
Critical pressure22,064 kPa
Liquid density958.40 kg/m³
Vapour density0.59800 kg/m³
Liquid viscosity (at saturation for Shah)0.28200 mPa·s
Vapour viscosity0.012300 mPa·s
Liquid thermal conductivity0.67900 W/(m·K)
Liquid specific heat4.2160 kJ/(kg·K)
Latent heat2,257.0 kJ/kg

Applying the formula below gives:

ResultValue
Reynolds number, total flow as liquid7,092.2
Liquid Prandtl number1.7510
All-liquid coefficient (Dittus–Boelter)1,176.3 W/(m²·K)
Dimensionless vapour velocity (regime map)4.7174
Lockhart–Martinelli parameter0.034167
Shah coefficient20,532 W/(m²·K)
Boyko–Kruzhilin coefficient33,308 W/(m²·K)
Two-phase multiplier (Müller-Steinhagen–Heck)655.20
Breber et al. coefficient, exponent 0.4521,771 W/(m²·K)
Void fraction (Chisholm slip)99.607 %
Stratified-flow coefficient13,301 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(h_{Shah} = h_{LO}\left[(1 - x)^{0.8} + \frac{3.8x^{0.76}(1 - x)^{0.04}}{P_r^{0.38}}\right], \quad h_{BK} = h_{LO}\left[1 + x\frac{\rho_L - \rho_V}{\rho_V}\right]^{1/2}\)

\(h_{Breber} = h_{LO}(\phi_{LO}^2)^{0.45}, \quad h_{strat} = 0.728\varepsilon_V^{0.75}\left[\frac{k_L^3\rho_L(\rho_L - \rho_V)g\lambda}{\mu_L(T_{sat} - T_w)D_i}\right]^{1/4}, \quad j^* = \frac{xG}{[D_ig\rho_V(\rho_L - \rho_V)]^{1/2}}\)

Variables

Symbol Meaning SI unit
\(G\) Total mass flux kg/(m²·s)
\(D_i\) Tube inside diameter m
\(x\) Vapour quality -
\(T_{sat} - T_w\) Saturation minus wall temperature K
\(P\) Pressure Pa
\(P_c\) Critical pressure Pa
\(\rho_L\) Liquid density kg/m³
\(\rho_V\) Vapour density kg/m³
\(\mu_L\) Liquid viscosity (at saturation for Shah) Pa·s
\(\mu_V\) Vapour viscosity Pa·s
\(k_L\) Liquid thermal conductivity W/(m·K)
\(c_{p,L}\) Liquid specific heat J/(kg·K)
\(\lambda\) Latent heat J/kg
\(Re_{LO}\) Reynolds number, total flow as liquid -
\(Pr_L\) Liquid Prandtl number -
\(h_{LO}\) All-liquid coefficient (Dittus–Boelter) W/(m²·K)
\(j^*\) Dimensionless vapour velocity (regime map) -
\(X_{tt}\) Lockhart–Martinelli parameter -
\(h_{Shah}\) Shah coefficient W/(m²·K)
\(h_{BK}\) Boyko–Kruzhilin coefficient W/(m²·K)
\(\phi_{LO}^2\) Two-phase multiplier (Müller-Steinhagen–Heck) -
\(h_{Breber}\) Breber et al. coefficient, exponent 0.45 W/(m²·K)
\(\varepsilon_V\) Void fraction (Chisholm slip) -
\(h_{strat}\) Stratified-flow coefficient W/(m²·K)

Method and standards

Two-phase multiplier and Nusselt-type correlations for condensation inside tubes.

Where it is used

  • Air-cooled condensers and tube-side process condensers.
  • Zone-by-zone condenser rating.

Common mistakes

  • Applying an annular-flow correlation to stratified flow.
  • Using wall-temperature properties in Shah's correlation.

Assumptions and limits

  • Local coefficient at one quality; integrate over the condensing range for the mean.

Questions and answers

Which result should I use?

Check the regime: annular flow (high j*, low X_tt) → Shah, Breber or Boyko–Kruzhilin; stratified flow → the Nusselt-type stratified value; in between, interpolate with Breber's rules.

Why does Shah fail near x = 1?

His multiplier contains (1 − x) terms and goes to zero for pure vapour; it is meant for qualities up to about 0.999 with a liquid film present.

What do the defaults represent?

An illustrative case: Steam condensing at 1 atm, x = 0.5, 20 mm tube, 100 kg/(m2 s). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Serth, Process Heat Transfer: Principles and Applications (Academic Press, 2007), sec. 11.6, eqs. 11.50 to 11.57 and Examples 11.4 and 11.5 (Shah 1979; Boyko and Kruzhilin 1967; Breber, Palen and Taborek 1980)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.