Flow Maldistribution: Loss of Heat Exchanger Effectiveness

Temperature effectiveness of a counterflow or parallelflow exchanger with a two-step inlet velocity maldistribution on one side, and the deterioration factor.

Refinery and petrochemicalChemical and fertiliserFood, dairy and textile

Inputs

Examples: High-NTU counterflow, 50:50 split, 1.3 x velocityUnbalanced parallelflow, turbulent pressure exponent

Accepted: 0.01 to 50
Accepted: 0 to 20
Accepted: 1 to 99 %
Accepted: 1 to 20
Accepted: 0.5 to 2

Results

Two parallel sub-exchangers with uniform flow on the other side and the same U; any maldistribution can conservatively be reduced to such a two-step profile (Shah). The pressure drop factor assumes Δp ∝ uⁿ in the fastest passages and is only indicative.

Velocity in the remaining area relative to the mean0.57143
Share of fluid 1 capacity rate in part A60.000%
NTU of sub-exchanger A0.75000
NTU of sub-exchanger B2.6250
Capacity ratio of sub-exchanger A1.0000
Capacity ratio of sub-exchanger B0.28571
Effectiveness of sub-exchanger A38.843%
Effectiveness of sub-exchanger B75.116%
Effectiveness with maldistribution53.353%
Effectiveness with uniform flow59.640%
Deterioration factor (P_ideal − P)/P_ideal10.542%
Approximate pressure drop increase factor3.4822

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: High-NTU counterflow, 50:50 split, 1.3 x velocity. The inputs, in the units selected above:

InputValue
NTU of the maldistributed fluid (UA/C₁)8.0000 -
Heat capacity rate ratio C₁/C₂1.0000 -
Share of free-flow area with the higher velocity50.000 %
Velocity in that share relative to the mean1.3000 -
Flow arrangementCounterflow
Pressure drop exponent, Δp ∝ uⁿ (1 laminar, about 1.8 turbulent)1.0000 -

Applying the formula below gives:

ResultValue
Velocity in the remaining area relative to the mean0.70000
Share of fluid 1 capacity rate in part A65.000 %
NTU of sub-exchanger A6.1538
NTU of sub-exchanger B11.429
Capacity ratio of sub-exchanger A1.3000
Capacity ratio of sub-exchanger B0.70000
Effectiveness of sub-exchanger A73.734 %
Effectiveness of sub-exchanger B99.004 %
Effectiveness with maldistribution82.579 %
Effectiveness with uniform flow88.889 %
Deterioration factor (P_ideal − P)/P_ideal7.0991 %
Approximate pressure drop increase factor1.3000

Open this example in the calculator and change any input.

Formula

\(P_1 = \frac{C_{1,A}}{C_1}P_{1,A} + \frac{C_{1,B}}{C_1}P_{1,B}, \quad \frac{C_{1,A}}{C_1} = \frac{u_A}{u}\frac{A_{o,A}}{A_o}\)

\(NTU_{1,A} = NTU_1\frac{A_{o,A}/A_o}{C_{1,A}/C_1}, \quad R_{1,A} = R_1\frac{C_{1,A}/C_1}{A_{o,A}/A_o}, \quad \Delta P_1^* = \frac{P_{1,ideal} - P_1}{P_{1,ideal}}\)

Variables

Symbol Meaning SI unit
\(NTU_1\) NTU of the maldistributed fluid (UA/C₁) -
\(R_1\) Heat capacity rate ratio C₁/C₂ -
\(A_{o,A}/A_o\) Share of free-flow area with the higher velocity -
\(u_A/u\) Velocity in that share relative to the mean -
\(\text{flow}\) Flow arrangement -
\(n\) Pressure drop exponent, Δp ∝ uⁿ (1 laminar, about 1.8 turbulent) -
\(u_B/u\) Velocity in the remaining area relative to the mean -
\(C_{1,A}/C_1\) Share of fluid 1 capacity rate in part A -
\(NTU_{1,A}\) NTU of sub-exchanger A -
\(NTU_{1,B}\) NTU of sub-exchanger B -
\(R_{1,A}\) Capacity ratio of sub-exchanger A -
\(R_{1,B}\) Capacity ratio of sub-exchanger B -
\(P_{1,A}\) Effectiveness of sub-exchanger A -
\(P_{1,B}\) Effectiveness of sub-exchanger B -
\(P_1\) Effectiveness with maldistribution -
\(P_{1,ideal}\) Effectiveness with uniform flow -
\(\Delta P_1^*\) Deterioration factor (P_ideal − P)/P_ideal -
\(\Delta p_{max}/\Delta p_{uniform}\) Approximate pressure drop increase factor -

Method and standards

Parallel sub-exchanger model of gross flow maldistribution on one fluid side.

Where it is used

  • Judging the effect of poor header or nozzle design.
  • Plate and compact exchangers with uneven port distribution.

Common mistakes

  • Assuming maldistribution always costs little: at high NTU and with laminar flow it can be large.
  • Forgetting that the fast passages also raise the pressure drop.

Assumptions and limits

  • Counterflow or parallelflow, constant U, uniform flow on the other side.

Questions and answers

Why is the loss only a few per cent?

Effectiveness curves flatten at high NTU, so the fast passages lose less than the slow ones gain; the loss grows with NTU for balanced counterflow and is worst for a 50:50 split.

Does it matter which fluid is maldistributed?

No: the analysis holds whether the maldistributed fluid is hot or cold, C_min or C_max.

What do the defaults represent?

An illustrative case: High-NTU counterflow, 50:50 split, 1.3 x velocity. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Shah and Sekulić, Fundamentals of Heat Exchanger Design (Wiley, 2003), sec. 12.1.1, eqs. 12.4 to 12.16 and Example 12.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.