Worked example
Example: Three 1-2 shells (P 0.45 each) in counterflow, R = 0.6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effectiveness of exchanger 1 | 45.000 % |
| Effectiveness of exchanger 2 (0 if absent) | 45.000 % |
| Effectiveness of exchanger 3 (0 if absent) | 45.000 % |
| Effectiveness of exchanger 4 (0 if absent) | 0 % |
| Heat capacity rate ratio C₁/C₂ | 0.60000 - |
| Overall coupling | Overall counterflow |
| Fluid 1 inlet temperature | 150.00 °C |
| Fluid 2 inlet temperature | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Number of exchangers | 3.0000 |
| Overall effectiveness (fluid 1) | 76.988 % |
| Overall effectiveness (fluid 2) = P₁R₁ | 46.193 % |
| Fluid 1 outlet temperature | 57.615 °C |
| Fluid 2 outlet temperature | 85.431 °C |
Open this example in the calculator and change any input.
Formula
\(P_{cf} = \frac{\prod_i\frac{1 - RP_i}{1 - P_i} - 1}{\prod_i\frac{1 - RP_i}{1 - P_i} - R}, \quad P_{cf}(R = 1) = \frac{\sum_iP_i/(1 - P_i)}{1 + \sum_iP_i/(1 - P_i)}\)
\(P_{pf} = \frac{1}{1 + R}\left\{1 - \prod_i\left[1 - (1 + R)P_i\right]\right\}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_1\) | Effectiveness of exchanger 1 | - |
| \(P_2\) | Effectiveness of exchanger 2 (0 if absent) | - |
| \(P_3\) | Effectiveness of exchanger 3 (0 if absent) | - |
| \(P_4\) | Effectiveness of exchanger 4 (0 if absent) | - |
| \(R_1\) | Heat capacity rate ratio C₁/C₂ | - |
| \(\text{coupling}\) | Overall coupling | - |
| \(T_{1,i}\) | Fluid 1 inlet temperature | K |
| \(T_{2,i}\) | Fluid 2 inlet temperature | K |
| \(n\) | Number of exchangers | - |
| \(T_{1,o}\) | Fluid 1 outlet temperature | K |
| \(T_{2,o}\) | Fluid 2 outlet temperature | K |
Method and standards
Effectiveness of exchangers coupled in series in overall counterflow or parallelflow.
Where it is used
- Trains of shells or exchangers in series.
- Exchanger networks and heat recovery trains.
Common mistakes
- Adding effectivenesses directly.
- Mixing up which fluid R refers to.
Assumptions and limits
- Same R for every unit; fluids mixed between units.
Questions and answers
When is overall counterflow coupling worth it?
Whenever the units are individually effective: counterflow coupling of two 0.61 and 0.75 units gives 0.82, while parallel coupling can never exceed 1/(1 + R).
How do I combine mixed arrangements?
Combine the counterflow-coupled group first, then treat its result as one exchanger in the next step.
What do the defaults represent?
An illustrative case: Three 1-2 shells (P 0.45 each) in counterflow, R = 0.6. Replace the inputs with your own data.