Worked example
Example: 2 MW back-pressure set, 45 bar(a) / 400 °C to 4 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet steam pressure (absolute) | 45.000 bar |
| Inlet steam condition | Superheated at the temperature below |
| Inlet steam temperature (superheated only) | 400.00 °C |
| Exhaust pressure (absolute) | 400.00 kPa |
| Turbine isentropic efficiency | 75.000 % |
| Gearbox and generator efficiency | 95.000 % |
| Electrical output wanted | 2,000.0 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Actual steam rate | 9.2527 kg/kWh |
| Steam flow for the output | 18,505 kg/h |
| Theoretical steam rate | 6.5925 kg/kWh |
| Isentropic enthalpy drop | 546.07 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(TSR = \frac{1}{h_1 - h_{2s}} \qquad ASR = \frac{1}{(h_1 - h_{2s})\,\eta_i\,\eta_g} \qquad \dot m_s = ASR \cdot P_{el}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | inlet pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated inlet | – |
| \(T_1\) | inlet temperature (superheated) | K |
| \(p_2\) | exhaust pressure, absolute | Pa |
| \(\eta_i\) | turbine isentropic efficiency | – |
| \(\eta_g\) | gearbox and generator efficiency | – |
| \(P_{el}\) | electrical output wanted | W |
| \(ASR\) | actual steam rate | kg/J |
| \(TSR\) | theoretical steam rate | kg/J |
| \(\dot m_s\) | steam flow for the output | kg/s |
| \(h_1 - h_{2s}\) | isentropic enthalpy drop | J/kg |
| \(h_1\), \(h_{2s}\) | inlet and isentropic exhaust enthalpy | J/kg |
Method and standards
Steam rate from the isentropic enthalpy drop (FireCAD IAPWS-IF97) and the turbine and generator efficiencies. Shown in kg/kWh; 1 kWh = 3.6 MJ.
Where it is used
- First sizing of a turbo-generator and its boiler.
- Steam balance of a cogeneration plant: how much steam the power takes.
- Comparing turbine offers at the same steam conditions.
Common mistakes
- Quoting the theoretical steam rate as the turbine's consumption.
- Forgetting the generator and gearbox losses.
- Using one steam rate for all loads: part-load steam rates rise.
Assumptions and limits
- Single expansion, constant efficiencies, steady flow.
References
- IAPWS R7-97(2012) IF97
- first law of thermodynamics
Questions and answers
What is a turbine's steam rate?
The steam it needs per kWh. Expanding from 45 bar(a) and 400 °C to 4 bar(a), the theoretical steam rate is 6.59 kg/kWh; at 75 % turbine and 95 % generator efficiency the actual rate is 9.25 kg/kWh, so 2 MW needs 18.5 t/h.
Why is a back-pressure turbine's steam rate so high?
Its enthalpy drop is small, so each kg makes little power. That is fine: the exhaust steam goes on to heat the process, so the fuel is used almost fully.
Is steam rate the same as heat rate?
No. Steam rate is kg of steam per kWh; heat rate is the heat added to that steam per kWh. Use the heat rate calculator for the second.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.