Supplementary Firing: Fuel Limit from Exhaust Oxygen

Maximum heat that can be fired in gas turbine exhaust from its oxygen content, the equivalent air, and the gas temperature rise, by Ganapathy's Eqs. (22)–(25).

Thermal power plantRefinery and petrochemicalChemical and fertiliserBurner and furnace

Inputs

Examples: 550,000 lb/h exhaust at 14 % O2, 30 MWSmall GT, 13 %, oil

Results

Burners need some oxygen left: practical firing stops well short of the maximum. Ganapathy also gives a shortcut rule for gas and oil firing; it is not computed here.

Equivalent air in the exhaust55.621t/h
Maximum heat that can be fired (LHV)45.344MW
Planned firing as a share of the maximum33.081%
Gas temperature rise from the planned firing526.77K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 550,000 lb/h exhaust at 14 % O2, 30 MW. The inputs, in the units selected above:

InputValue
Exhaust gas flow249.48 t/h
Oxygen in the exhaust (by volume, wet basis)14.000 %
Exhaust molar mass29.500 kg/kmol
Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb)Natural gas (730)
Fuel LHV/HHV ratio90.000 %
Planned firing (LHV)30.000 MW
Exhaust specific heat1.1300 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Equivalent air in the exhaust164.72 t/h
Maximum heat that can be fired (LHV)131.21 MW
Planned firing as a share of the maximum22.863 %
Gas temperature rise from the planned firing383.10 K

Open this example in the calculator and change any input.

Formula

\(W_a = \frac{W_g\,O \times 32}{0.23\,M_g}, \quad Q_{max} = W_a\,\frac{LHV}{A\,HHV}, \quad \Delta T = \frac{Q}{W_g c_{pg}}\)

Variables

Symbol Meaning SI unit
\(W_g\) Exhaust gas flow kg/s
\(O\) Oxygen in the exhaust (by volume, wet basis) -
\(M_g\) Exhaust molar mass kg/kmol
\(A\) Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb) -
\(LHV/HHV\) Fuel LHV/HHV ratio -
\(Q\) Planned firing (LHV) W
\(c_{pg}\) Exhaust specific heat J/(kg·K)
\(W_a\) Equivalent air in the exhaust kg/s
\(Q_{max}\) Maximum heat that can be fired (LHV) W
\(Q/Q_{max}\) Planned firing as a share of the maximum -
\(\Delta T\) Gas temperature rise from the planned firing K

Method and standards

Ganapathy's oxygen balance; LHV/(A·HHV) ≈ 0.00124 for gas and oil.

Where it is used

  • HRSG duct burner sizing.
  • Checking supplementary firing schemes.

Common mistakes

  • Firing to zero oxygen.
  • Using HHV heat input with LHV limits.

Assumptions and limits

  • Exhaust oxygen known; complete combustion.
  • Exhaust oxygen must be above zero; a planned firing above the maximum is flagged, and its temperature rise then cannot be reached.
  • The oxygen is by volume on the wet exhaust, consistent with the wet molar mass M_g in the volume-to-mass conversion.
  • Table 2.4 figures are lb of air per MMBtu; the page converts them to SI.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.27
  • Eqs. (22)–(25)
  • and Table 2.4

Questions and answers

Why can gas turbine exhaust be fired?

It holds 14–16 % oxygen, enough to burn fuel without fresh air.

How far can it go?

In theory until the oxygen is used; burners need a few per cent left, so firing to about 2,000 °F is a practical limit.

What is 0.23?

The mass fraction of oxygen in air.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.