FireCADCalc

Power per Tonne of Steam for Two Inlet Conditions

Turbine shaft work per tonne of steam for two inlet pressure–temperature pairs to the same exhaust pressure (IF97), and the gain from the higher conditions.

Process steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)BoilerSteam turbine

Inputs

Examples: 45 bar vs 110 bar67 vs 87 bar

Results

Higher inlet conditions also need more heat per tonne of steam; compare power per unit of fuel for the full picture.

Shaft work: multiply by the gearbox and generator efficiencies for electrical output.

Shaft work per tonne, A149.06kWh/t
Shaft work per tonne, B200.56kWh/t
Gain of B over A34.551%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 45 bar vs 110 bar. The inputs, in the units selected above:

InputValue
Inlet pressure A (absolute)46.000 bar
Inlet temperature A440.00 °C
Inlet pressure B (absolute)111.00 bar
Inlet temperature B540.00 °C
Exhaust pressure (absolute)2.5000 bar
Isentropic efficiency80.000 %

Applying the formula below gives:

ResultValue
Shaft work per tonne, A149.06 kWh/t
Shaft work per tonne, B200.56 kWh/t
Gain of B over A34.551 %

Open this example in the calculator and change any input.

Formula

\(w = \eta_s [h(p_1, T_1) - h(p_e, s_1)]\)

Variables

Symbol Meaning SI unit
\(p_A\) Inlet pressure A (absolute) Pa
\(T_A\) Inlet temperature A K
\(p_B\) Inlet pressure B (absolute) Pa
\(T_B\) Inlet temperature B K
\(p_e\) Exhaust pressure (absolute) Pa
\(\eta_s\) Isentropic efficiency -
\(w_A\) Shaft work per tonne, A J/kg
\(w_B\) Shaft work per tonne, B J/kg
\(w_B/w_A − 1\) Gain of B over A -

Method and standards

IF97 expansion.

Where it is used

  • Cogeneration upgrade studies.
  • Boiler pressure selection.

Common mistakes

  • Gauge pressures.

Assumptions and limits

  • Same efficiency.
  • The work is turbine shaft work; gearbox and generator losses are not included.
  • Wet exhaust (dryness below about 88 %) is flagged for each inlet.
  • Each inlet must be superheated (or supercritical) steam; an inlet temperature at or below the saturation temperature is rejected.

References

  • Isentropic expansion with efficiency; IAPWS-IF97

Questions and answers

Why have sugar mills moved to high-pressure boilers?

Each tonne of process steam passing a turbine makes much more power from higher inlet conditions.

Does fuel use rise?

Yes, a little per tonne of steam; the extra power usually pays well with export.

Efficiency same for both?

Larger high-pressure turbines are usually more efficient: adjust if known.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.