Worked example
Example: 45 bar vs 110 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet pressure A (absolute) | 46.000 bar |
| Inlet temperature A | 440.00 °C |
| Inlet pressure B (absolute) | 111.00 bar |
| Inlet temperature B | 540.00 °C |
| Exhaust pressure (absolute) | 2.5000 bar |
| Isentropic efficiency | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Shaft work per tonne, A | 149.06 kWh/t |
| Shaft work per tonne, B | 200.56 kWh/t |
| Gain of B over A | 34.551 % |
Open this example in the calculator and change any input.
Formula
\(w = \eta_s [h(p_1, T_1) - h(p_e, s_1)]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_A\) | Inlet pressure A (absolute) | Pa |
| \(T_A\) | Inlet temperature A | K |
| \(p_B\) | Inlet pressure B (absolute) | Pa |
| \(T_B\) | Inlet temperature B | K |
| \(p_e\) | Exhaust pressure (absolute) | Pa |
| \(\eta_s\) | Isentropic efficiency | - |
| \(w_A\) | Shaft work per tonne, A | J/kg |
| \(w_B\) | Shaft work per tonne, B | J/kg |
| \(w_B/w_A − 1\) | Gain of B over A | - |
Method and standards
IF97 expansion.
Where it is used
- Cogeneration upgrade studies.
- Boiler pressure selection.
Common mistakes
- Gauge pressures.
Assumptions and limits
- Same efficiency.
- The work is turbine shaft work; gearbox and generator losses are not included.
- Wet exhaust (dryness below about 88 %) is flagged for each inlet.
- Each inlet must be superheated (or supercritical) steam; an inlet temperature at or below the saturation temperature is rejected.
References
- Isentropic expansion with efficiency; IAPWS-IF97
Questions and answers
Why have sugar mills moved to high-pressure boilers?
Each tonne of process steam passing a turbine makes much more power from higher inlet conditions.
Does fuel use rise?
Yes, a little per tonne of steam; the extra power usually pays well with export.
Efficiency same for both?
Larger high-pressure turbines are usually more efficient: adjust if known.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.