Worked example
Example: Ideal: 150 bar(a) / 535 °C, reheat 35 bar(a) to 535 °C, 0.1 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet steam pressure (absolute) | 150.00 bar |
| Main steam temperature | 535.00 °C |
| Reheat pressure (absolute) | 35.000 bar |
| Reheat temperature | 535.00 °C |
| Condenser pressure (absolute) | 10.000 kPa |
| Turbine isentropic efficiency (each section) | 100.00 % |
| Feed pump isentropic efficiency | 100.00 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cycle thermal efficiency | 43.641 % |
| Net work per kg of steam | 1,632.6 kJ/kg |
| Specific steam consumption | 2.2051 kg/kWh |
| Turbine exhaust dryness | 88.140 % |
| Heat added (boiler and reheater) | 3,741.0 kJ/kg |
| Back work ratio | 0.91619 % |
Open this example in the calculator and change any input.
Formula
\(h_2 = h_1 - \eta_t\left[h_1 - h(p_{rh}, s_1)\right] \qquad h_4 = h_3 - \eta_t\left[h_3 - h(p_2, s_3)\right],\ h_3 = h(p_{rh}, T_{rh})\)
\(w_{net} = (h_1 - h_2) + (h_3 - h_4) - w_p \qquad q_{in} = (h_1 - h_6) + (h_3 - h_2) \qquad \eta_{th} = \frac{w_{net}}{q_{in}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | main steam pressure, absolute | Pa |
| \(T_1\) | main steam temperature | K |
| \(p_{rh}\) | reheat pressure, absolute | Pa |
| \(T_{rh}\) | reheat temperature | K |
| \(p_2\) | condenser pressure, absolute | Pa |
| \(\eta_t\) | turbine isentropic efficiency, each section | – |
| \(\eta_p\) | pump isentropic efficiency | – |
| \(\eta_{th}\) | cycle thermal efficiency | – |
| \(w_{net}\) | net work per kg | J/kg |
| \(SSC\) | specific steam consumption | kg/J |
| \(x_4\) | turbine exhaust dryness | – |
| \(q_{in}\) | heat added in boiler and reheater | J/kg |
| \(BWR\) | back work ratio | – |
| \(w_p\) | pump work | J/kg |
| \(h_1\), \(h_2\), \(h_3\), \(h_4\) | main steam, HP exhaust, reheat outlet, LP exhaust enthalpies | J/kg |
| \(h_6\) | feedwater enthalpy after the pump | J/kg |
| \(s_1\), \(s_3\) | entropy at main steam and reheat outlet | J/(kg·K) |
Method and standards
Rankine cycle with one reheat; isentropic efficiencies on both turbine sections and the pump; states by FireCAD's IAPWS-IF97. Reheater pressure drop neglected.
Where it is used
- Utility and large captive power plants with reheat boilers.
- Comparing reheat pressures and temperatures at the concept stage.
- Teaching the effect of reheat on efficiency and exhaust moisture.
Common mistakes
- Forgetting the reheat heat in the heat added.
- Ignoring the 8–10 % pressure drop of a real reheater.
- Comparing with a non-reheat cycle at different condenser pressure.
Assumptions and limits
- One reheat, no feed heating, no pressure drops; saturated liquid from the condenser.
- Main steam must be superheated: unlike the simple and regenerative cycle pages there is no dry-saturated option.
- The reheat outlet enthalpy must be at least the HP exhaust enthalpy; a negative reheater duty is rejected.
References
- IAPWS R7-97(2012) IF97
- first and second laws of thermodynamics
Questions and answers
How much does reheat improve efficiency?
It depends on the conditions: compare this page with the simple Rankine calculator at the same main steam. Reheat also gives much drier exhaust. With 150 bar(a) and 535 °C main steam, reheat at 35 bar(a) back to 535 °C and a 0.1 bar(a) condenser, the ideal cycle reaches 43.6 % with 88.1 % dry exhaust.
What reheat pressure is best?
There is no single figure: lower reheat pressures raise the average heat-addition temperature less, higher ones leave wetter exhaust. Try several reheat pressures here and compare.
Why do large plants use reheat?
High main steam pressure alone gives wet exhaust that erodes blades; reheat dries it and raises efficiency.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.