FireCADCalc

Reheat Rankine Cycle Efficiency Calculator

Thermal efficiency, net work and exhaust dryness of a Rankine cycle with one reheat, from main and reheat steam conditions and the condenser pressure (IAPWS-IF97).

Thermal power plantIAPWS-IF97 (water and steam)BoilerSteam turbine

Inputs

Examples: Ideal: 150 bar(a) / 535 °C, reheat 35 bar(a) to 535 °C, 0.1 bar(a)Real: same, turbine 88 %, pump 80 %100 bar(a) / 500 °C, reheat 20 bar(a) to 500 °C, 0.08 bar(a), 85 % / 75 %

Results

Cycle thermal efficiency43.641%
Net work per kg of steam1,632.6kJ/kg
Specific steam consumption2.2051kg/kWh
Turbine exhaust dryness88.140%
Heat added (boiler and reheater)3,741.0kJ/kg
Back work ratio0.91619%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ideal: 150 bar(a) / 535 °C, reheat 35 bar(a) to 535 °C, 0.1 bar(a). The inputs, in the units selected above:

InputValue
Inlet steam pressure (absolute)150.00 bar
Main steam temperature535.00 °C
Reheat pressure (absolute)35.000 bar
Reheat temperature535.00 °C
Condenser pressure (absolute)10.000 kPa
Turbine isentropic efficiency (each section)100.00 %
Feed pump isentropic efficiency100.00 %

Applying the formula below gives:

ResultValue
Cycle thermal efficiency43.641 %
Net work per kg of steam1,632.6 kJ/kg
Specific steam consumption2.2051 kg/kWh
Turbine exhaust dryness88.140 %
Heat added (boiler and reheater)3,741.0 kJ/kg
Back work ratio0.91619 %

Open this example in the calculator and change any input.

Formula

\(h_2 = h_1 - \eta_t\left[h_1 - h(p_{rh}, s_1)\right] \qquad h_4 = h_3 - \eta_t\left[h_3 - h(p_2, s_3)\right],\ h_3 = h(p_{rh}, T_{rh})\)

\(w_{net} = (h_1 - h_2) + (h_3 - h_4) - w_p \qquad q_{in} = (h_1 - h_6) + (h_3 - h_2) \qquad \eta_{th} = \frac{w_{net}}{q_{in}}\)

Variables

Symbol Meaning SI unit
\(p_1\) main steam pressure, absolute Pa
\(T_1\) main steam temperature K
\(p_{rh}\) reheat pressure, absolute Pa
\(T_{rh}\) reheat temperature K
\(p_2\) condenser pressure, absolute Pa
\(\eta_t\) turbine isentropic efficiency, each section –
\(\eta_p\) pump isentropic efficiency –
\(\eta_{th}\) cycle thermal efficiency –
\(w_{net}\) net work per kg J/kg
\(SSC\) specific steam consumption kg/J
\(x_4\) turbine exhaust dryness –
\(q_{in}\) heat added in boiler and reheater J/kg
\(BWR\) back work ratio –
\(w_p\) pump work J/kg
\(h_1\), \(h_2\), \(h_3\), \(h_4\) main steam, HP exhaust, reheat outlet, LP exhaust enthalpies J/kg
\(h_6\) feedwater enthalpy after the pump J/kg
\(s_1\), \(s_3\) entropy at main steam and reheat outlet J/(kg·K)

Method and standards

Rankine cycle with one reheat; isentropic efficiencies on both turbine sections and the pump; states by FireCAD's IAPWS-IF97. Reheater pressure drop neglected.

Where it is used

  • Utility and large captive power plants with reheat boilers.
  • Comparing reheat pressures and temperatures at the concept stage.
  • Teaching the effect of reheat on efficiency and exhaust moisture.

Common mistakes

  • Forgetting the reheat heat in the heat added.
  • Ignoring the 8–10 % pressure drop of a real reheater.
  • Comparing with a non-reheat cycle at different condenser pressure.

Assumptions and limits

  • One reheat, no feed heating, no pressure drops; saturated liquid from the condenser.
  • Main steam must be superheated: unlike the simple and regenerative cycle pages there is no dry-saturated option.
  • The reheat outlet enthalpy must be at least the HP exhaust enthalpy; a negative reheater duty is rejected.

References

  • IAPWS R7-97(2012) IF97
  • first and second laws of thermodynamics

Questions and answers

How much does reheat improve efficiency?

It depends on the conditions: compare this page with the simple Rankine calculator at the same main steam. Reheat also gives much drier exhaust. With 150 bar(a) and 535 °C main steam, reheat at 35 bar(a) back to 535 °C and a 0.1 bar(a) condenser, the ideal cycle reaches 43.6 % with 88.1 % dry exhaust.

What reheat pressure is best?

There is no single figure: lower reheat pressures raise the average heat-addition temperature less, higher ones leave wetter exhaust. Try several reheat pressures here and compare.

Why do large plants use reheat?

High main steam pressure alone gives wet exhaust that erodes blades; reheat dries it and raises efficiency.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.