FireCADCalc

Labyrinth (Gland) Seal Steam Leakage by Martin's Formula

Steam leakage through a turbine labyrinth or gland seal from upstream steam state, downstream pressure, number of throttles and clearance area by Martin's formula.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 30 bar 300 °C to 1.2 bar, 12 teeth, 400 mm, 0.4 mmLP gland 2 bar saturated to 0.95 bar, 6 teeth

Results

Martin's formula assumes subsonic flow at the last throttle and full carry-over loss between teeth; the flow coefficient K (0.6–0.8 for sharp teeth) carries the geometry. Clearances open with rubs: use measured values for existing machines.

The pressure ratio 0.040 is below 0.231: the last throttle chokes, so the leakage no longer rises as the downstream pressure falls and Martin's formula overstates it. Treat the result as an upper bound, or add teeth.

Clearance area502.65mm²
Upstream specific volume0.081175m³/kg
Leakage1,972.3kg/h
Pressure ratio p_n/p_0 below which the last throttle chokes, 0.85/√(N + 1.5)0.23134

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 bar 300 °C to 1.2 bar, 12 teeth, 400 mm, 0.4 mm. The inputs, in the units selected above:

InputValue
Upstream pressure (absolute)30.000 bar
Upstream steam temperature (≤ saturation = dry saturated)300.00 °C
Downstream pressure (absolute)1.2000 bar
Number of throttles (teeth)12.000 -
Shaft diameter at the seal400.00 mm
Radial clearance0.40000 mm
Flow coefficient0.70000 -

Applying the formula below gives:

ResultValue
Clearance area502.65 mm²
Upstream specific volume0.081175 m³/kg
Leakage1,972.3 kg/h
Pressure ratio p_n/p_0 below which the last throttle chokes, 0.85/√(N + 1.5)0.23134

Open this example in the calculator and change any input.

Formula

\(\dot m = KA\sqrt{\frac{p_0}{v_0}}\sqrt{\frac{1 - (p_n/p_0)^2}{N - \ln(p_n/p_0)}}, \quad A = \pi Dc, \quad r_{cr} = \frac{0.85}{\sqrt{N + 1.5}}\)

Variables

Symbol Meaning SI unit
\(p_0\) Upstream pressure (absolute) Pa
\(T_0\) Upstream steam temperature (≤ saturation = dry saturated) K
\(p_n\) Downstream pressure (absolute) Pa
\(N\) Number of throttles (teeth) -
\(D\) Shaft diameter at the seal m
\(c\) Radial clearance m
\(K\) Flow coefficient -
\(A\) Clearance area m²
\(v_0\) Upstream specific volume m³/kg
\(\dot m\) Leakage kg/s
\(r_{cr}\) Pressure ratio p_n/p_0 below which the last throttle chokes (Stodola) -

Method and standards

Martin's formula.

Where it is used

  • Gland steam and leak-off estimates.
  • Effect of worn seals on heat rate.

Common mistakes

  • Using diametral instead of radial clearance.
  • Applying it at choking pressure ratios with few teeth.

Assumptions and limits

  • Straight-through or stepped labyrinth with flow coefficient K.
  • Subsonic flow at the last throttle is assumed. A note appears when p_n/p_0 is below r_cr = 0.85/√(N + 1.5), Stodola's criterion for choking at the last throttle; the formula then overstates the leakage, and no choked-flow model is applied.
  • At 22 MPa and above the upstream state is taken at the entered pressure and temperature.

References

  • Martin (1908) labyrinth leakage formula
  • as given in turbomachinery texts (e.g. Stodola; Kearton, Steam Turbine Theory and Practice)

Questions and answers

Why do more teeth leak less?

Each throttle takes part of the pressure drop and the kinetic energy is lost between teeth, so the flow per unit pressure difference falls roughly as 1/√N.

How much does clearance matter?

Leakage is directly proportional to clearance: a rub that doubles it doubles the leakage.

What do the defaults give?

30 bar, 300 °C steam to 1.2 bar through 12 teeth on a 400 mm shaft at 0.4 mm clearance: about 2 t/h.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.