Worked example
Example: 87 bar, 515 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Turbine inlet pressure (absolute) | 87.000 bar |
| Turbine inlet temperature | 515.00 °C |
| Process (exhaust or extraction) pressure (absolute) | 2.5000 bar |
| Condenser pressure (absolute) | 10.000 kPa |
| Process steam demand | 100.00 t/h |
| Steam to the extraction-condensing turbine | 130.00 t/h |
| Isentropic efficiency (each section) | 80.000 % |
| Gearbox and generator efficiency | 96.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power, back-pressure turbine | 17.966 MW |
| Power, extraction-condensing turbine | 26.497 MW |
| Extra power | 8.5308 MW |
| Condenser heat rejected | 18.086 MW |
| Extra steam per extra kWh | 3.5167 kg/kWh |
Open this example in the calculator and change any input.
Formula
\(P_{BP} = \dot m_p (h_1 - h_e)\eta_g, \quad P_{EC} = [\dot m_t (h_1 - h_e) + (\dot m_t - \dot m_p)(h_e - h_c)]\eta_g\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | Turbine inlet pressure (absolute) | Pa |
| \(T_1\) | Turbine inlet temperature | K |
| \(p_e\) | Process (exhaust or extraction) pressure (absolute) | Pa |
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(\dot m_p\) | Process steam demand | kg/s |
| \(\dot m_t\) | Steam to the extraction-condensing turbine | kg/s |
| \(\eta_s\) | Isentropic efficiency (each section) | - |
| \(\eta_g\) | Gearbox and generator efficiency | - |
| \(P_{BP}\) | Power, back-pressure turbine | W |
| \(P_{EC}\) | Power, extraction-condensing turbine | W |
| \(\Delta P\) | Extra power | W |
| \(\dot Q_c\) | Condenser heat rejected | W |
| \(SR\) | Extra steam per extra kWh | kg/J |
Method and standards
IF97 expansion.
Where it is used
- Cogeneration configuration studies.
- Sugar and distillery turbine selection.
Common mistakes
- Absolute and gauge pressures mixed.
Assumptions and limits
- Same efficiency for both sections; a note warns when the condenser exhaust is wetter than about 88 %.
- The extra steam (ṁ_t − ṁ_p) needs extra boiler fuel, which this comparison does not count: weigh the extra power against that fuel.
- With no condensing flow the extra steam rate is not shown.
- The inlet must be superheated (or supercritical) steam; a liquid inlet state is rejected.
References
- Expansion with isentropic efficiency per section; IAPWS-IF97 enthalpies and entropies
Questions and answers
Why does the condensing tail cost so much steam per kWh?
Most of the condensing steam's heat goes to the condenser, not the shaft.
When is EC worth it?
When surplus fuel (bagasse, off-season) and an export tariff exist.
Season and off-season?
EC turbines run the off-season fully condensing; BP turbines stop with the process.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.