FireCADCalc

Furnace Exit Gas Temperature (Well-Stirred Furnace Model)

Furnace exit gas temperature and wall heat absorption from adiabatic flame temperature, gas flow, wall area, effective emissivity and wall temperature.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoilerBurner and furnace

Inputs

Examples: Bagasse furnaceOil-fired package boiler

Results

Well-stirred (zero-dimensional) model: the gas leaving is at the uniform radiating temperature; calibrate ε_eff against a measured exit temperature.

Furnace exit gas temperature957.17°C
Heat absorbed by the walls37.141MW
Share of the available heat absorbed49.448%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bagasse furnace. The inputs, in the units selected above:

InputValue
Adiabatic flame temperature1,600.0 °C
Flue gas flow160.00 t/h
Mean gas specific heat (T_exit to T_ad)1.3000 kJ/(kg·K)
Effective water-wall area600.00 m²
Effective furnace emissivity50.000 %
Wall surface temperature300.00 °C

Applying the formula below gives:

ResultValue
Furnace exit gas temperature957.17 °C
Heat absorbed by the walls37.141 MW
Share of the available heat absorbed49.448 %

Open this example in the calculator and change any input.

Formula

\(\dot m_g \bar c_p (T_{ad} - T_e) = \sigma \varepsilon_{eff} A (T_e^4 - T_w^4) = \dot Q_r, \quad \dot Q_{ad} = \dot m_g \bar c_p (T_{ad} - T_w)\)

Variables

Symbol Meaning SI unit
\(T_{ad}\) Adiabatic flame temperature K
\(\dot m_g\) Flue gas flow kg/s
\(\bar c_p\) Mean gas specific heat (T_exit to T_ad) J/(kg·K)
\(A\) Effective water-wall area m²
\(\varepsilon_{eff}\) Effective furnace emissivity -
\(T_w\) Wall surface temperature K
\(T_e\) Furnace exit gas temperature K
\(\dot Q_r\) Heat absorbed by the walls W
\(\dot Q_r/\dot Q_{ad}\) Share of the available heat absorbed -
\(\dot Q_{ad}\) heat the gas would give up cooling from T_ad to the wall temperature W
\(\sigma\) Stefan–Boltzmann constant W/(m²·K⁴)

Method and standards

Well-stirred (zero-dimensional) furnace: the heat the gas loses from the adiabatic flame temperature to the exit equals the radiation from gas at the exit temperature to the walls; solved by bisection between the wall and flame temperatures. The share absorbed is relative to cooling the gas to the wall temperature, not to the fuel heat input.

Where it is used

  • Furnace sizing.
  • Fuel change studies.

Common mistakes

  • Using the full-range cp at low temperatures.

Assumptions and limits

  • Uniform gas temperature.
  • The mean specific heat over T_e to T_ad depends on the unknown T_e: iterate it if needed.

References

  • Well-stirred furnace model ṁ c̄_p (T_ad − T_e) = σ ε A (T_e⁴ − T_w⁴) (Hottel and Sarofim)
  • Stefan–Boltzmann constant 5.670374419 × 10⁻⁸ W/m²K⁴ (CODATA 2018)

Questions and answers

Why does exit temperature matter?

It sets slagging of superheaters, superheat and the split between radiant and convective duty.

Is the furnace really well stirred?

No; the model is a first estimate. Tune the effective emissivity to a measured FEGT and then use it for changes.

Wet biomass?

Lower adiabatic temperature and higher gas flow give a cooler furnace exit.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.