Furnace Water-Wall Average and Peak Heat Flux

Average heat flux on furnace water walls from the heat absorbed and the projected wall area, and the peak flux for a peaking factor.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoilerBurner and furnace

Inputs

Examples: 30 MW on 400 m2High duty

The heat taken up by the furnace water walls only (evaporator duty in the furnace), not the heat released by the fuel or the whole boiler duty.
The flat (projected) area of the furnace walls covered by water-wall tubes, not the tube surface. Include roof and hopper as your design convention does.
From the boiler maker or a furnace heat-flux profile; 1.6 is a FireCAD starting value, not a sourced figure.

Results

Compare the peak flux with the critical heat flux at the local pressure and quality.

Average heat flux133.33kW/m²
Peak heat flux240.00kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 MW on 400 m2. The inputs, in the units selected above:

InputValue
Heat absorbed by the water walls30.000 MW
Projected water-wall area400.00 m²
Peak-to-average factor1.6000 -

Applying the formula below gives:

ResultValue
Average heat flux75.000 kW/m²
Peak heat flux120.00 kW/m²

Open this example in the calculator and change any input.

Formula

\(q_{avg} = \frac{\dot Q_a}{A_p}, \quad q_{peak} = k_p q_{avg}\)

Variables

Symbol Meaning SI unit
\(\dot Q_a\) Heat absorbed by the water walls W
\(A_p\) Projected water-wall area m²
\(k_p\) Peak-to-average factor -
\(q_{avg}\) Average heat flux W/m²
\(q_{peak}\) Peak heat flux W/m²

Method and standards

Definition: the average flux is the heat absorbed by the water walls over their projected area; the peak flux applies a peak-to-average factor from the boiler maker or a measured profile.

Where it is used

  • Furnace design checks.
  • Tube failure investigations.

Common mistakes

  • Tube surface area used.

Assumptions and limits

  • The average is over the whole projected area; the peak factor gives the local maximum (burner zone, flame impingement). Its default, 1.6, is a FireCAD starting value, not a sourced figure.
  • The heat input must be the water-wall absorption, not the heat released; the area is the flat projected wall area, with roof and hopper as your convention counts them.
  • The peak flux is not compared with a CHF here: use the critical heat flux calculators.

References

  • q = Q/A (definition); peak factor by design practice

Questions and answers

Why projected area?

Furnace absorption is customarily referred to the flat wall area, not the tube surface.

Peak factor?

Burner zone and flame impingement raise local flux; designs use a factor from experience.

Why care?

High flux with poor circulation or scale can lead to overheating and tube failure.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.