Cold-End Metal Temperature vs Acid Dew Point

Metal temperature at the cold end of an economiser or air heater from the gas and water or air temperatures and film coefficients, and its margin to the acid dew point.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoilerEconomiser and air preheater

Inputs

Examples: Economiser cold end: gas 150 °C, water 105 °C, h_g 60, h_w 3000, ADP 125 °CAir heater cold end: gas 140 °C, air 30 °C, 45 / 40, ADP 115 °CAir heater with steam coil: gas 140 °C, air 70 °C, 45 / 40, ADP 115 °C

From the acid dew point calculator.

Results

The metal is below the acid dew point: sulphuric acid condenses and corrodes the cold end. Raise the feedwater or air temperature (steam coil air heater, bypass).

Metal temperature at the cold end88.235°C
Margin above the acid dew point-26.765K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Economiser cold end: gas 150 °C, water 105 °C, h_g 60, h_w 3000, ADP 125 °C. The inputs, in the units selected above:

InputValue
Flue gas temperature at the cold end150.00 °C
Water or air temperature at the cold end105.00 °C
Gas-side film coefficient60.000 W/(m²·K)
Water- or air-side film coefficient3,000.0 W/(m²·K)
Acid dew point of the flue gas125.00 °C

Applying the formula below gives:

ResultValue
Metal temperature at the cold end105.88 °C
Margin above the acid dew point-19.118 K

Open this example in the calculator and change any input.

Formula

\(T_m = \frac{h_g\,T_g + h_c\,T_c}{h_g + h_c} \qquad \Delta T = T_m - T_{adp}\)

Variables

Symbol Meaning SI unit
\(T_g\) gas temperature at the cold end K
\(T_c\) water or air temperature at the cold end K
\(h_g\) gas-side coefficient W/(m²·K)
\(h_c\) water- or air-side coefficient W/(m²·K)
\(T_{adp}\) acid dew point K
\(T_m\) metal temperature K
\(\Delta T\) margin above the acid dew point K

Method and standards

Steady heat balance across a thin wall: the metal temperature divides the gas-to-coolant difference in proportion to the film resistances (wall and fouling resistance neglected).

Where it is used

  • Setting minimum feedwater temperature for economisers.
  • Air heater cold-end protection.
  • Diagnosing cold-end corrosion and fouling.

Common mistakes

  • Comparing the gas temperature, not the metal temperature, with the dew point.
  • Using average instead of cold-end temperatures.
  • Ignoring part load, when gas leaves colder.

Assumptions and limits

  • Thin clean wall; local temperatures at the cold end.
  • Both coefficients must be on the same area. For finned tubes or a large outside-to-inside diameter ratio, refer the gas-side coefficient to the coolant-side area (h_g × A_g/A_c, with fin efficiency) before entering it; otherwise the metal temperature is misstated.

References

  • Thin-wall metal temperature from two film coefficients

Questions and answers

How cold is the metal at an economiser's cold end?

Close to the water, because the water side transfers heat far better. Gas at 150 °C and water at 105 °C with coefficients of 60 and 3000 W/(m²·K) give a metal at 106 °C, 19 K below a 125 °C acid dew point: acid will condense.

Why are air heaters safer?

Gas and air coefficients are similar, so the metal sits halfway between them: gas at 140 °C and air at 30 °C give about 88 °C, still below the dew point unless the air is preheated.

What can I do?

Raise the feedwater temperature (deaerator pressure, feed heater), preheat the air with a steam coil or recirculate hot air, or use corrosion-resistant cold-end elements.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.