Worked example
Example: Convection bank. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flue gas flow | 160.00 t/h |
| Gas temperature in the bank | 500.00 °C |
| Flue gas molar mass | 28.500 kg/kmol |
| Gas pressure (absolute) | 100.00 kPa |
| Duct width across the tubes | 6.0000 m |
| Tube length exposed (duct depth) | 5.0000 m |
| Tubes in one row | 60.000 - |
| Tube outside diameter | 50.800 mm |
| Velocity limit for the fuel's ash | 12.000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Free flow area | 14.760 m² |
| Gas density | 0.44335 kg/m³ |
| Gas velocity | 6.7918 m/s |
| Share of the limit | 56.598 % |
Open this example in the calculator and change any input.
Formula
\(A_f = L (W - n d_o), \quad \rho_g = \frac{p M_g}{1000\,R\,T_g}, \quad v = \frac{\dot m_g}{\rho_g A_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | Flue gas flow | kg/s |
| \(T_g\) | Gas temperature in the bank | K |
| \(M_g\) | Flue gas molar mass | kg/kmol |
| \(p\) | Gas pressure (absolute) | Pa |
| \(W\) | Duct width across the tubes | m |
| \(L\) | Tube length exposed (duct depth) | m |
| \(n\) | Tubes in one row | - |
| \(d_o\) | Tube outside diameter | m |
| \(v_{lim}\) | Velocity limit for the fuel's ash | m/s |
| \(A_f\) | Free flow area | m² |
| \(\rho_g\) | Gas density | kg/m³ |
| \(v\) | Gas velocity | m/s |
| \(R\) | universal gas constant, 8.314 J/(mol·K) (the 1000 converts \(M_g\) from kg/kmol) | J/(mol·K) |
| \(v/v_{lim}\) | Share of the limit | - |
Method and standards
Continuity through the free area between the tubes of one row, with the ideal-gas density at the bank temperature and pressure.
Where it is used
- Convection bank and economiser design.
- Erosion failure analysis.
Common mistakes
- Duct area used without tubes.
Assumptions and limits
- Uniform flow.
- In-line banks: the gap between tubes of one row sets the area. In staggered banks the diagonal gap can be smaller and then sets the peak velocity; it is not computed here.
References
- Free area A = L (W − n d); ideal gas density; velocity limit by fuel ash (user input)
Questions and answers
Why does erosion rise so fast with velocity?
Erosion rate rises roughly with the cube of velocity or more.
What limit?
Low for high-ash or sandy fuels (bagasse, husk); higher for oil and gas: use your design practice.
Staggered banks?
Check the diagonal gap too; the minimum gap sets the peak velocity.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.