FireCADCalc

Air Preheater X-Ratio and Gas- and Air-Side Effectiveness

X-ratio (air to gas heat capacity rate) and gas-side and air-side effectiveness of an air preheater from its four terminal temperatures (no leakage correction).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolEconomiser and air preheater

Inputs

Examples: Tubular APHRegenerative

Results

Leakage of cold air into the gas lowers the measured gas exit temperature; correct it before judging performance.

X-ratio (ṁc_p)air/(ṁc_p)gas0.78947
Gas-side effectiveness69.231%
Air-side effectiveness87.692%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Tubular APH. The inputs, in the units selected above:

InputValue
Gas in340.00 °C
Gas out150.00 °C
Air in30.000 °C
Air out280.00 °C

Applying the formula below gives:

ResultValue
X-ratio (ṁc_p)air/(ṁc_p)gas0.76000
Gas-side effectiveness61.290 %
Air-side effectiveness80.645 %

Open this example in the calculator and change any input.

Formula

\(X = \frac{T_{g,in} - T_{g,out}}{T_{a,out} - T_{a,in}}, \quad \varepsilon_g = \frac{T_{g,in} - T_{g,out}}{T_{g,in} - T_{a,in}}, \quad \varepsilon_a = \frac{T_{a,out} - T_{a,in}}{T_{g,in} - T_{a,in}}\)

Variables

Symbol Meaning SI unit
\(T_{g,in}\) Gas in K
\(T_{g,out}\) Gas out K
\(T_{a,in}\) Air in K
\(T_{a,out}\) Air out K
\(X\) X-ratio (ṁc_p)air/(ṁc_p)gas -
\(\varepsilon_g\) Gas-side effectiveness -
\(\varepsilon_a\) Air-side effectiveness -

Method and standards

Definitions from an energy balance with no leakage: the X-ratio equals the ratio of air to gas heat capacity rates because the heat the gas gives up is the heat the air takes. Both effectivenesses are referred to the gas-in to air-in span.

Where it is used

  • Air heater performance tests.
  • Fouling and leakage monitoring.

Common mistakes

  • Leakage-diluted gas temperature used.

Assumptions and limits

  • Constant specific heats; no leakage. With air leaking into the gas the measured gas outlet is low, which makes the X-ratio from temperatures read high; correct the gas outlet temperature for leakage first.
  • Temperatures that cross (gas out below air in, or air out above gas in) are rejected: each effectiveness must stay at or below 1.

References

  • Energy balance definitions: X = (T_g,in − T_g,out)/(T_a,out − T_a,in); effectiveness on the gas-in to air-in span

Questions and answers

What does a low X-ratio mean?

Less air than gas heat capacity: the air heats a lot but the gas cools less.

Why correct for leakage?

Leaked air dilutes and cools the gas without heat transfer.

Typical gas-side effectiveness?

Around 60–75 % for regenerative air heaters.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.