Two-Phase Friction Multiplier (Lockhart–Martinelli, Chisholm C)

Martinelli parameter and Chisholm two-phase friction multiplier for steam–water from pressure and quality (IF97 properties), and the two-phase pressure drop.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 70 bar, 10 %Low pressure flashing lineViscous liquid, turbulent vapour (C = 12)Both viscous (C = 5)

The form of the Martinelli parameter follows C: 20 turbulent liquid and vapour, 12 viscous liquid and turbulent vapour, 10 turbulent liquid and viscous vapour, 5 both viscous. Other values use the turbulent–turbulent form.
Total flow over the tube bore area. Used for the Reynolds numbers, which set the X form when C is 12 or 10 and check the regime.

Results

Δp_l is the friction drop of the liquid part of the flow, (1 − x)ṁ, flowing alone in the same tube.

Martinelli parameter, in the form set by C0.29510
Reynolds number of the liquid flowing alone1,095.7
Reynolds number of the vapour flowing alone5,293.9
Two-phase multiplier53.148
Two-phase frictional pressure drop26.574kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 70 bar, 10 %. The inputs, in the units selected above:

InputValue
Pressure (absolute)70.000 bar
Steam quality10.000 %
Chisholm constant: 20 tt, 12 vt, 10 tv, 5 vv (liquid–vapour; t turbulent, v viscous)20.000 -
Pressure drop of the liquid flowing alone2.0000 kPa
Total mass flux1,000.0 kg/(m²·s)
Tube inside diameter50.000 mm

Applying the formula below gives:

ResultValue
Martinelli parameter, in the form set by C1.8792
Reynolds number of the liquid flowing alone493,063
Reynolds number of the vapour flowing alone264,697
Two-phase multiplier11.926
Two-phase frictional pressure drop23.852 kPa

Open this example in the calculator and change any input.

Formula

\(Re_l = \frac{G(1-x)D}{\mu_l}, \quad Re_v = \frac{G x D}{\mu_v}, \quad f = \frac{16}{Re} \text{ (viscous)} \text{ or } 0.046\,Re^{-0.2} \text{ (turbulent)}\)

\(X^2 = \frac{f_l}{f_v}\left(\frac{1-x}{x}\right)^2 \frac{\rho_v}{\rho_l}, \quad \phi_l^2 = 1 + \frac{C}{X} + \frac{1}{X^2}, \quad \Delta p_{tp} = \phi_l^2\,\Delta p_l\)

For both phases turbulent this is \(X_{tt} = \left(\frac{1-x}{x}\right)^{0.9}\left(\frac{\rho_v}{\rho_l}\right)^{0.5}\left(\frac{\mu_l}{\mu_v}\right)^{0.1}\).

Variables

Symbol Meaning SI unit
\(p\) Pressure (absolute) Pa
\(x\) Steam quality -
\(C\) Chisholm constant: 20 tt, 12 vt, 10 tv, 5 vv (liquid–vapour; t turbulent, v viscous) -
\(G\) Total mass flux kg/(m²·s)
\(D\) Tube inside diameter m
\(\Delta p_l\) Pressure drop of the liquid flowing alone Pa
\(X\) Martinelli parameter, in the form set by C -
\(X_{tt}\) X with both phases turbulent -
\(Re_l\), \(Re_v\) Reynolds numbers of the liquid and the vapour flowing alone -
\(f\), \(f_l\), \(f_v\) Fanning friction factor; of the liquid and of the vapour flowing alone -
\(\rho_l\), \(\rho_v\) Saturated liquid and vapour densities (IF97) kg/m³
\(\mu_l\), \(\mu_v\) Saturated liquid and vapour viscosities (IAPWS 2008) Pa·s
\(\phi_l^2\) Two-phase multiplier -
\(\Delta p_{tp}\) Two-phase frictional pressure drop Pa

Method and standards

Lockhart–Martinelli separated-flow model with Chisholm's form of the liquid multiplier. The Martinelli parameter X is the square root of the ratio of the liquid-alone to the vapour-alone friction gradients, each with the viscous (16/Re) or turbulent (0.046 Re^−0.2) friction factor that the chosen C stands for, as Lockhart and Martinelli and Chisholm define it. Saturated-liquid and vapour properties from IAPWS-IF97 and IAPWS 2008. A note appears when the Reynolds numbers (viscous below 1000, turbulent above 2000) do not match the regime of C.

Where it is used

  • Riser and evaporator pressure drop.
  • Flashing lines.

Common mistakes

  • Total flow used for the liquid-alone drop.

Assumptions and limits

  • Separated-flow model.
  • The form of X follows C (20, 12, 10 or 5); any other C uses the turbulent–turbulent form.

References

  • Lockhart and Martinelli
  • Chem. Eng. Prog. 45 (1949); Chisholm
  • Int. J. Heat Mass Transfer 10 (1967): φ_l² = 1 + C/X + 1/X²; Collier and Thome
  • Convective Boiling and Condensation; X_tt with IAPWS-IF97 densities and IAPWS 2008 viscosities

Questions and answers

What is Δp_l?

The friction loss if only the liquid fraction of the flow ran in the pipe.

Which C?

20 when both phases are turbulent; 12, 10 or 5 for the laminar combinations.

Accuracy?

Scatter of ±30 % or more is normal for two-phase friction correlations.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators