FireCADCalc

Superheater Steam-Side Pressure Drop

Steam-side friction pressure drop of a superheater from steam flow, number of parallel tubes, bore, length and steam conditions (Darcy–Weisbach, IAPWS).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 50 t/h, 60 tubes 38 mm ID, 45 m each, 68 bar(a), 300 to 485 °C20 t/h, 30 tubes 33 mm, 30 m, 47 bar(a), 260 to 400 °C150 t/h, 120 tubes 40 mm, 60 m, 110 bar(a), 320 to 540 °C

Results

Friction pressure drop30.597kPa
Mean steam velocity7.0457m/s
Reynolds number425,435
Darcy friction factor0.020955
Steam density at the mean temperature39.217kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h, 60 tubes 38 mm ID, 45 m each, 68 bar(a), 300 to 485 °C. The inputs, in the units selected above:

InputValue
Steam flow through the superheater50,000 kg/h
Parallel tubes (elements)60.000 -
Tube inside diameter38.000 mm
Length of one tube (with bends as equivalent length)45.000 m
Tube roughness0.046000 mm
Inlet pressure (absolute)68.000 bar
Steam temperature in300.00 °C
Steam temperature out485.00 °C

Applying the formula below gives:

ResultValue
Friction pressure drop21.410 kPa
Mean steam velocity8.2869 m/s
Reynolds number321,919
Darcy friction factor0.021378
Steam density at the mean temperature24.630 kg/m³

Open this example in the calculator and change any input.

Formula

\(v = \frac{\dot m / N}{\rho\,\pi d_i^2/4} \qquad Re = \frac{\rho v d_i}{\mu} \qquad \Delta p = f\,\frac{L}{d_i}\,\frac{\rho v^2}{2}\)

\(\frac{1}{\sqrt f} = -2\log_{10}\left(\frac{\varepsilon/d_i}{3.7} + \frac{2.51}{Re\sqrt f}\right)\ (\text{turbulent}), \qquad f = \frac{64}{Re}\ (\text{laminar})\)

Variables

Symbol Meaning SI unit
\(\dot m\) steam flow kg/s
\(N\) parallel tubes –
\(d_i\) tube bore m
\(L\) tube length m
\(\varepsilon\) roughness m
\(p\) inlet pressure Pa
\(T_1\) steam temperature in K
\(T_2\) steam temperature out K
\(\Delta p\) friction pressure drop Pa
\(v\) mean velocity m/s
\(Re\) Reynolds number –
\(f\) Darcy friction factor –
\(\rho\) steam density at mean temperature kg/m³
\(\mu\) steam viscosity Pa·s

Method and standards

Darcy–Weisbach with the Colebrook–White friction factor; steam density and viscosity from FireCAD's IAPWS-IF97 and IAPWS 2008 at the inlet pressure and mean temperature.

Where it is used

  • Superheater design and rerating.
  • Checking drum pressure needed for turbine inlet pressure.
  • Flow distribution studies.

Common mistakes

  • Using inlet density for the whole length when temperature rises a lot.
  • Forgetting bends and headers.
  • Using total flow per tube.

Assumptions and limits

  • Friction only (no acceleration or header losses); properties at the arithmetic mean temperature and inlet pressure. The specific volume of steam is not linear in temperature and falls as the pressure drops, so for long or high-duty superheaters split them into sections.
  • The steam entering must be dry saturated or superheated (not more than 1 K below saturation) and the outlet temperature not below the inlet.

References

  • Darcy–Weisbach with Colebrook–White friction factor
  • IAPWS R7-97 IF97
  • IAPWS 2008 viscosity

Questions and answers

What is a superheater's pressure drop?

For 50 t/h through 60 tubes of 38 mm bore, 45 m long, at 68 bar(a) from 300 to 485 °C, steam flows at 8.3 m/s and loses 21 kPa to friction.

Why does pressure drop matter?

The boiler drum must run that much above the turbine inlet pressure, and the drop shares flow between parallel tubes; too little drop gives poor flow distribution.

Does it include bends and headers?

Enter bends as equivalent length; header and inlet/outlet losses are extra.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.