Worked example
Example: 50 t/h, 60 tubes 38 mm ID, 45 m each, 68 bar(a), 300 to 485 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam flow through the superheater | 50,000 kg/h |
| Parallel tubes (elements) | 60.000 - |
| Tube inside diameter | 38.000 mm |
| Length of one tube (with bends as equivalent length) | 45.000 m |
| Tube roughness | 0.046000 mm |
| Inlet pressure (absolute) | 68.000 bar |
| Steam temperature in | 300.00 °C |
| Steam temperature out | 485.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Friction pressure drop | 21.410 kPa |
| Mean steam velocity | 8.2869 m/s |
| Reynolds number | 321,919 |
| Darcy friction factor | 0.021378 |
| Steam density at the mean temperature | 24.630 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(v = \frac{\dot m / N}{\rho\,\pi d_i^2/4} \qquad Re = \frac{\rho v d_i}{\mu} \qquad \Delta p = f\,\frac{L}{d_i}\,\frac{\rho v^2}{2}\)
\(\frac{1}{\sqrt f} = -2\log_{10}\left(\frac{\varepsilon/d_i}{3.7} + \frac{2.51}{Re\sqrt f}\right)\ (\text{turbulent}), \qquad f = \frac{64}{Re}\ (\text{laminar})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | steam flow | kg/s |
| \(N\) | parallel tubes | – |
| \(d_i\) | tube bore | m |
| \(L\) | tube length | m |
| \(\varepsilon\) | roughness | m |
| \(p\) | inlet pressure | Pa |
| \(T_1\) | steam temperature in | K |
| \(T_2\) | steam temperature out | K |
| \(\Delta p\) | friction pressure drop | Pa |
| \(v\) | mean velocity | m/s |
| \(Re\) | Reynolds number | – |
| \(f\) | Darcy friction factor | – |
| \(\rho\) | steam density at mean temperature | kg/m³ |
| \(\mu\) | steam viscosity | Pa·s |
Method and standards
Darcy–Weisbach with the Colebrook–White friction factor; steam density and viscosity from FireCAD's IAPWS-IF97 and IAPWS 2008 at the inlet pressure and mean temperature.
Where it is used
- Superheater design and rerating.
- Checking drum pressure needed for turbine inlet pressure.
- Flow distribution studies.
Common mistakes
- Using inlet density for the whole length when temperature rises a lot.
- Forgetting bends and headers.
- Using total flow per tube.
Assumptions and limits
- Friction only (no acceleration or header losses); properties at the arithmetic mean temperature and inlet pressure. The specific volume of steam is not linear in temperature and falls as the pressure drops, so for long or high-duty superheaters split them into sections.
- The steam entering must be dry saturated or superheated (not more than 1 K below saturation) and the outlet temperature not below the inlet.
References
- Darcy–Weisbach with Colebrook–White friction factor
- IAPWS R7-97 IF97
- IAPWS 2008 viscosity
Questions and answers
What is a superheater's pressure drop?
For 50 t/h through 60 tubes of 38 mm bore, 45 m long, at 68 bar(a) from 300 to 485 °C, steam flows at 8.3 m/s and loses 21 kPa to friction.
Why does pressure drop matter?
The boiler drum must run that much above the turbine inlet pressure, and the drop shares flow between parallel tubes; too little drop gives poor flow distribution.
Does it include bends and headers?
Enter bends as equivalent length; header and inlet/outlet losses are extra.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.