FireCADCalc

Steam Drum Water Holding Time

Water held in a steam drum between two levels and the time it lasts at the steaming rate if feedwater is lost, from the drum size and pressure.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Drum 1 500 mm x 8 m, levels 600 to 750 mm, 70 bar(a), 50 t/hDrum 1 200 mm x 5 m, 450 to 600 mm, 45 bar(a), 20 t/hDrum 1 800 mm x 12 m, 750 to 900 mm, 110 bar(a), 120 t/h

Results

Holding time between the levels95.225s
Water between the levels1,322.6kg
Volume between the levels1.7879m³
Density of saturated water739.72kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Drum 1 500 mm x 8 m, levels 600 to 750 mm, 70 bar(a), 50 t/h. The inputs, in the units selected above:

InputValue
Drum inside diameter1,500.0 mm
Drum straight length8.0000 m
Lower level above the drum bottom (e.g. low-low trip)600.00 mm
Upper level above the drum bottom (e.g. normal water level, at most D)750.00 mm
Drum pressure (absolute)70.000 bar
Steaming rate50,000 kg/h

Applying the formula below gives:

ResultValue
Holding time between the levels95.225 s
Water between the levels1,322.6 kg
Volume between the levels1.7879 m³
Density of saturated water739.72 kg/m³

Open this example in the calculator and change any input.

Formula

\(A(h) = R^2\cos^{-1}\!\left(\frac{R-h}{R}\right) - (R-h)\sqrt{2Rh - h^2} \qquad R = \frac{D}{2}\)

\(V = L\,[A(h_2) - A(h_1)] \qquad m = \rho\,V \qquad t_h = \frac{m}{\dot m_s}\)

Variables

Symbol Meaning SI unit
\(D\) drum inside diameter m
\(L\) drum straight length m
\(h_1\) lower level above the drum bottom m
\(h_2\) upper level above the drum bottom m
\(p\) drum pressure, absolute Pa
\(\dot m_s\) steaming rate kg/s
\(t_h\) holding time between the levels s
\(m\) water between the levels kg
\(V\) volume between the levels m³
\(\rho\) density of saturated water kg/m³
\(A(h)\) area of the circular segment up to level \(h\) m²

Method and standards

Volume of a horizontal cylinder between two liquid levels (circular segments) times the density of saturated water from FireCAD's IAPWS-IF97.

Where it is used

  • Sizing steam drums of water-tube boilers.
  • Checking response time to feed interruptions.
  • Setting drum level alarm margins.

Common mistakes

  • Using total drum volume instead of the volume between levels.
  • Ignoring swell and shrink.
  • Using cold-water density.

Assumptions and limits

  • Dished ends and drum internals are ignored (ends add a little, internals take a little).
  • Steady steaming rate with no feedwater and no blowdown.
  • Steam bubbles below the surface (swell) reduce the real water content.

References

  • Geometry of a horizontal cylinder
  • IAPWS R7-97(2012) IF97 (saturated water density)

Questions and answers

How long does a drum last without feedwater?

Water between the levels ÷ steaming rate. A 1 500 mm × 8 m drum at 70 bar(a) holds 1.79 m³ (1 323 kg) between 600 and 750 mm; at 50 t/h that is 95 seconds.

Why is the density so low?

Drum water is at saturation: 740 kg/m³ at 70 bar(a), 672 kg/m³ at 110 bar(a).

Is the water in the tubes counted?

No, only the drum between the two levels. Swell and shrink on load changes and the water in risers and downcomers change the real time.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.