Worked example
Example: 60 kW/m², 184 °C water, 4 mm steel, 1 mm scale of 1 W/(m·K). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat flux through the tube wall | 60.000 kW/m² |
| Boiler water temperature (saturation) | 184.00 °C |
| Water-side (boiling) coefficient | 20,000 W/(m²·K) |
| Tube wall thickness | 4.0000 mm |
| Conductivity of the tube steel | 45.000 W/(m·K) |
| Scale thickness | 1.0000 mm |
| Conductivity of the scale | 1.0000 W/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water-side metal temperature, clean tube | 187.00 °C |
| Gas-side metal temperature, clean tube | 192.33 °C |
| Gas-side metal temperature with scale | 252.33 °C |
| Metal temperature rise caused by the scale | 60.000 K |
| Thermal resistance of the scale t_s / k_s | 0.001000 m²·K/W |
Open this example in the calculator and change any input.
Formula
\(T_{in} = T_w + \frac{q}{h_w}, \quad T_{o,0} = T_{in} + q\, \frac{t_m}{k_m}\)
\(\Delta T_s = q\, \frac{t_s}{k_s}, \quad T_o = T_{o,0} + \Delta T_s, \quad T_{in,s} = T_{in} + \Delta T_s\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q\) | Heat flux through the tube wall | W/m² |
| \(T_w\) | Boiler water temperature (saturation) | K |
| \(h_w\) | Water-side (boiling) coefficient | W/(m²·K) |
| \(t_m\) | Tube wall thickness | m |
| \(k_m\) | Conductivity of the tube steel | W/(m·K) |
| \(t_s\) | Scale thickness | m |
| \(k_s\) | Conductivity of the scale | W/(m·K) |
| \(T_{in}\) | Water-side metal temperature, clean tube | K |
| \(T_{o,0}\) | Gas-side metal temperature, clean tube | K |
| \(T_o\) | Gas-side metal temperature with scale | K |
| \(\Delta T_s\) | Metal temperature rise caused by the scale | K |
| \(R_s\) | Thermal resistance of the scale t_s / k_s | m²·K/W |
| \(T_{in,s}\) | water-side metal temperature behind the scale (not an output) | K |
Method and standards
At one heat flux each layer's temperature drop is q × its thermal resistance; scale adds a resistance t_s/k_s between the metal and the water.
Worked example
A tube at 60 kW/m² has boiler water at 184 °C, water-side coefficient 20 000 W/(m²·K), 4 mm steel wall (45 W/(m·K)) and 1 mm of scale (1 W/(m·K)).
- Water side of metal = 184 + 60 000/20 000 = 187 °C
- Gas side, clean = 187 + 60 000 × 0.004/45 = 192.3 °C
- Scale adds 60 000 × 0.001/1 = 60 K: gas side 252.3 °C
Where it is used
- Boiler attendant and operator examinations: why feedwater must be treated.
- Investigating tube bulges and failures.
- Justifying water treatment and blowdown.
Common mistakes
- Using a scale conductivity far from the real scale (it varies tenfold).
- Assuming the heat flux falls in proportion.
- Ignoring that the hottest tubes have the highest flux.
Assumptions and limits
- Flat-wall layers; same heat flux with and without scale, and the same flux through every layer. For a thick tube the flux on the inside surface is higher than on the outside by the diameter ratio; enter the inside-surface flux to be on the safe side for the water film and scale.
- A note appears when the gas-side metal is above about 450 °C; compare the result with the allowable temperature of your tube material.
- Scale conductivity entered by the user.
References
- One-dimensional conduction through layers in series (Fourier's law)
Questions and answers
How much hotter does 1 mm of scale make a tube at 60 kW/m²?
With a scale conductivity of 1 W/(m·K), 60 K: the gas-side metal goes from 192 °C to 252 °C.
Why is scale dangerous?
The heat must still pass, so the metal runs hotter until it creeps or bulges. 0.5 mm of porous silicate scale at 150 kW/m² can add over 350 K.
Does scale waste fuel?
Some, but mostly the gas leaves hotter. Overheating and tube failure are the bigger danger.