FireCADCalc

Two-Massecuite Boiling Scheme Balance

Sugar, final molasses and both massecuites in a two-massecuite scheme (second sugar as seed), from syrup solids and the purities, by SJM balances (Hugot ch. 33).

Sugar mill and cogeneration

Inputs

Examples: 15 t/h syrup solidsLow purity juice

Results

Hugot's two-massecuite figures: first massecuite about 75, second 60 purity; final molasses 35–41.

Commercial sugar (dry solids)11,557kg/h
Final molasses (dry solids)3,442.6kg/h
Second sugar (dry solids)3,177.8kg/h
Second massecuite (dry solids)6,620.4kg/h
First massecuite (dry solids)18,178kg/h
First massecuite purity85.524%
First massecuite per tonne cane134.41L/t
Second massecuite per tonne cane46.913L/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 t/h syrup solids. The inputs, in the units selected above:

InputValue
Syrup dry solids15,000 kg/h
Syrup purity85.000 %
Commercial sugar purity99.000 %
Second sugar purity88.000 %
Second massecuite purity (first molasses)62.000 %
Final molasses purity38.000 %
First massecuite brix92.000 %
Second massecuite brix96.000 %
Massecuite density1,470.0 kg/m³
Crushing rate100.00 t/h

Applying the formula below gives:

ResultValue
Commercial sugar (dry solids)11,557 kg/h
Final molasses (dry solids)3,442.6 kg/h
Second sugar (dry solids)3,177.8 kg/h
Second massecuite (dry solids)6,620.4 kg/h
First massecuite (dry solids)18,178 kg/h
First massecuite purity85.524 %
First massecuite per tonne cane134.41 L/t
Second massecuite per tonne cane46.913 L/t

Open this example in the calculator and change any input.

Formula

\(S = S_0\frac{j - m}{s - m}, \quad M = S_0 - S, \quad S_2 = M\frac{p_2 - m}{s_2 - p_2}, \quad Q_2 = M\frac{s_2 - m}{s_2 - p_2}, \quad Q_1 = S_0 + S_2\)

Variables

Symbol Meaning SI unit
\(S_0\) Syrup dry solids kg/s
\(j\) Syrup purity -
\(s\) Commercial sugar purity -
\(s_2\) Second sugar purity -
\(p_2\) Second massecuite purity (first molasses) -
\(m\) Final molasses purity -
\(B_1\) First massecuite brix -
\(B_2\) Second massecuite brix -
\(\rho_m\) Massecuite density kg/m³
\(A\) Crushing rate kg/s
\(S\) Commercial sugar (dry solids) kg/s
\(M\) Final molasses (dry solids) kg/s
\(S_2\) Second sugar (dry solids) kg/s
\(Q_2\) Second massecuite (dry solids) kg/s
\(Q_1\) First massecuite (dry solids) kg/s
\(p_1\) First massecuite purity -
\(v_1\) First massecuite per tonne cane m³/kg
\(v_2\) Second massecuite per tonne cane m³/kg

Method and standards

Dry-solids and sucrose balances (SJM).

Where it is used

  • Planning boiling schemes.
  • Massecuite volumes for pan and crystalliser sizing.

Common mistakes

  • Mixing apparent and true purities.
  • Forgetting that the seed returns to the first massecuite.

Assumptions and limits

  • No losses; second massecuite from first molasses only.
  • A second massecuite purity at or above the syrup purity is flagged as unrealistic.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 33
  • boiling schemes and the SJM balance (eqns 33.36, 39.1–39.3)
  • pp. 670–677

Questions and answers

How is the second sugar used?

As seed (footing) for the first massecuite, so all commercial sugar leaves from the first massecuite.

Where does the first molasses go?

It becomes the second massecuite; its purity equals the second massecuite purity in this scheme.

When is two-massecuite enough?

For low-purity juices; richer juices need three massecuites to exhaust the molasses.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.