FireCADCalc

Pan Station Steam per Tonne Cane (Hugot)

Steam used by the pans per tonne of cane from the A, B and C massecuite volumes per tonne cane, Hugot's coefficients and the boiling method (eqn 33.29).

Sugar mill and cogenerationBoiler

Inputs

Examples: Hugot example: A batch, B and C continuousAll batch pans

Hugot: A 95–140, B 50–55, C 35–40 L per tonne cane.

Results

Hugot's example: 140, 54 and 36 L/t cane of A (batch pans) and B and C (continuous pans) massecuite take about 137 kg steam per tonne cane.

Steam for A per tonne cane84.892kg/t
Steam for B per tonne cane28.577kg/t
Steam for C per tonne cane22.861kg/t
Total per tonne cane136.33kg/t
Pan steam13.633t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: A batch, B and C continuous. The inputs, in the units selected above:

InputValue
Crushing rate100.00 t/h
A massecuite per tonne cane140.00 L/t
B massecuite per tonne cane54.000 L/t
C massecuite per tonne cane36.000 L/t
Massecuite density1,470.0 kg/m³
Steam per kg A massecuite0.27500 -
Steam per kg B massecuite0.30000 -
Steam per kg C massecuite0.36000 -
Boiling method, A massecuiteBatch pans (1.5)
Boiling method, B massecuiteContinuous pans (1.2)
Boiling method, C massecuiteContinuous pans (1.2)

Applying the formula below gives:

ResultValue
Steam for A per tonne cane84.892 kg/t
Steam for B per tonne cane28.577 kg/t
Steam for C per tonne cane22.861 kg/t
Total per tonne cane136.33 kg/t
Pan steam13.633 t/h

Open this example in the calculator and change any input.

Formula

\(s_i = v_i\,\rho_m\,k_i\,m_i, \quad s = s_A + s_B + s_C, \quad \dot m_s = s A\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(v_A\) A massecuite per tonne cane m³/kg
\(v_B\) B massecuite per tonne cane m³/kg
\(v_C\) C massecuite per tonne cane m³/kg
\(\rho_m\) Massecuite density kg/m³
\(k_A\) Steam per kg A massecuite -
\(k_B\) Steam per kg B massecuite -
\(k_C\) Steam per kg C massecuite -
\(m_A\) Boiling method, A massecuite -
\(m_B\) Boiling method, B massecuite -
\(m_C\) Boiling method, C massecuite -
\(s_A\) Steam for A per tonne cane kg/kg
\(s_B\) Steam for B per tonne cane kg/kg
\(s_C\) Steam for C per tonne cane kg/kg
\(s\) Total per tonne cane kg/kg
\(\dot m_s\) Pan steam kg/s

Method and standards

Hugot's eqn 33.29 per massecuite.

Where it is used

  • Factory steam balances.
  • Comparing batch and continuous pans.

Common mistakes

  • Entering massecuite in t/t cane as L/kg.
  • Leaving out the jigger steam.

Assumptions and limits

  • Steam at pan calandria conditions. Hugot's coefficients are kg of heating steam or vapour per kg of massecuite; the page does not correct them for the steam pressure.
  • The method factor is 1.2 for continuous pans, 1.5 for batch pans and 2.25 for batch pans that also use jigger steam (live steam blown into the bottom of the pan to help circulation).

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 33
  • eqn 33.29 and example
  • pp. 664–667

Questions and answers

Where do the coefficients come from?

Hugot: kilograms of steam per kilogram of massecuite, rising from A to C because low grades are boiled from thinner, poorer feeds and take longer.

Why 1.5 for batch pans?

Batch boiling wastes steam in steaming out, graining and part-load periods; continuous pans need about 1.2.

Typical totals?

Literature figures in Hugot run from 115 to 170 kg/t cane.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.