Worked example
Example: A strike 30 m3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Massecuite volume of the strike | 30.000 m³ |
| Massecuite density | 1,470.0 kg/m³ |
| Massecuite brix | 93.000 % |
| Feed (syrup or molasses) brix | 65.000 % |
| Share of the strike that is footing | 30.000 % |
| Heating surface | 180.00 m² |
| Mean evaporation rate | 59.000 kg/(m²·h) |
| Other time per cycle (fill, steam out, drop) | 1.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Massecuite mass | 44.100 t |
| Water evaporated | 13.298 t |
| Boiling time | 1.2522 h |
| Cycle time | 2.2522 h |
| Strikes per day | 10.656 |
Open this example in the calculator and change any input.
Formula
\(M_m = \rho_m V, \quad E = (1 - \phi)M_m\left(\frac{B_m}{B_f} - 1\right), \quad t_b = \frac{E}{g S}, \quad n = \frac{24\ \mathrm h}{t_b + t_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Massecuite volume of the strike | m³ |
| \(\rho_m\) | Massecuite density | kg/m³ |
| \(B_m\) | Massecuite brix | - |
| \(B_f\) | Feed (syrup or molasses) brix | - |
| \(\phi\) | Share of the strike that is footing | - |
| \(S\) | Heating surface | m² |
| \(g\) | Mean evaporation rate | kg/(m²·s) |
| \(t_a\) | Other time per cycle (fill, steam out, drop) | s |
| \(M_m\) | Massecuite mass | kg |
| \(E\) | Water evaporated | kg |
| \(t_b\) | Boiling time | s |
| \(t_c\) | Cycle time | s |
| \(n\) | Strikes per day | - |
Method and standards
Solids balance and Hugot's mean rates.
Where it is used
- Planning pan stations.
- Checking pan performance.
Common mistakes
- Using the footing brix as feed brix.
- Using peak instead of mean rates.
Assumptions and limits
- Feed and massecuite brix steady through the strike.
- Movement water and wash water added during boiling are not counted in E; they add evaporation, so the boiling time can be longer than shown.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 33
- evaporation in pans (Table 33.7) and boiling times
- pp. 660–675
Questions and answers
Why does the footing reduce evaporation?
The footing is already massecuite; only the rest of the strike is built from feed that must be concentrated.
Why do C strikes take so long?
Low-purity liquor is viscous, circulates slowly and evaporates at a third of the rate of footings.
Is the rate constant?
No: Hugot shows it falling from over 100 to about 20 kg/(m²·h) as the strike rises; use a mean.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.