FireCADCalc

Massecuite Crystal Content and Purity Drop

Crystal % dry solids and % massecuite and the purity drop from massecuite, crystal and mother-liquor (molasses) purities and the massecuite brix.

Sugar mill and cogeneration

Inputs

Examples: A massecuiteC massecuite

Results

Crystal % dry solids36.667%
Crystal % massecuite35.933%
Purity drop P_m − M22.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: A massecuite. The inputs, in the units selected above:

InputValue
Massecuite purity86.000 %
Crystal purity99.500 %
Mother liquor (molasses) purity66.000 %
Massecuite brix92.000 %

Applying the formula below gives:

ResultValue
Crystal % dry solids59.701 %
Crystal % massecuite54.925 %
Purity drop P_m − M20.000 %

Open this example in the calculator and change any input.

Formula

\(c_s = \frac{P_m - M}{S - M}, \quad c_m = c_s\,Bx_m\)

Variables

Symbol Meaning SI unit
\(P_m\) Massecuite purity -
\(S\) Crystal purity -
\(M\) Mother liquor (molasses) purity -
\(Bx_m\) Massecuite brix -
\(c_s\) Crystal % dry solids -
\(c_m\) Crystal % massecuite -
\(\Delta P\) Purity drop P_m − M -

Method and standards

Purity balance.

Where it is used

  • Pan and crystalliser control.
  • Boiling scheme design.

Common mistakes

  • Molasses purity from a different strike.

Assumptions and limits

  • Apparent purities.

References

  • Purity (solids and pol) balance of crystal and mother liquor

Questions and answers

Why is purity drop watched?

A larger drop means more sucrose crystallised and better exhaustion.

Crystal % massecuite vs % solids?

Multiply crystal % solids by the massecuite brix.

Same formula as SJM?

Yes, the same balance with the massecuite in place of juice.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.