Worked example
Example: Quadruple 120/111/100/85/55. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condensate leaving the first calandria | 30,000 kg/h |
| Temperature of that condensate | 120.00 °C |
| Temperature of calandria 2 | 111.00 °C |
| Temperature of calandria 3 | 100.00 °C |
| Temperature of calandria 4 | 85.000 °C |
| Temperature of calandria 5 | 55.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour flashed into calandria 2 | 514.42 kg/h |
| Vapour flashed into calandria 3 | 607.61 kg/h |
| Vapour flashed into calandria 4 | 794.52 kg/h |
| Vapour flashed into calandria 5 | 1,489.6 kg/h |
| Total vapour flashed | 3,406.2 kg/h |
| Condensate left at the end | 26,594 kg/h |
| Share flashed | 11.354 % |
Open this example in the calculator and change any input.
Formula
\(F_i = \dot m_{L,i-1}\frac{h_f(T_{i-1}) - h_f(T_i)}{h_g(T_i) - h_f(T_i)}, \quad \dot m_{L,i} = \dot m_{L,i-1} - F_i\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_c\) | Condensate leaving the first calandria | kg/s |
| \(T_0\) | Temperature of that condensate | K |
| \(T_1\) | Temperature of calandria 2 | K |
| \(T_2\) | Temperature of calandria 3 | K |
| \(T_3\) | Temperature of calandria 4 | K |
| \(T_4\) | Temperature of calandria 5 | K |
| \(F_1\) | Vapour flashed into calandria 2 | kg/s |
| \(F_2\) | Vapour flashed into calandria 3 | kg/s |
| \(F_3\) | Vapour flashed into calandria 4 | kg/s |
| \(F_4\) | Vapour flashed into calandria 5 | kg/s |
| \(\Sigma F\) | Total vapour flashed | kg/s |
| \(\dot m_L\) | Condensate left at the end | kg/s |
| \(\Sigma F/\dot m_c\) | Share flashed | - |
Method and standards
Adiabatic flash with IF97.
Where it is used
- Evaporator steam economy.
- Condensate system design.
Common mistakes
- Flashing condensate into a hotter vessel.
- Mixing condensates of different temperatures without a balance.
Assumptions and limits
- Saturated condensate; no heat loss.
- Only the condensate leaving the first calandria is followed through four stages. Each later calandria's own condensate, which joins the cascade in Hugot's scheme, is not added, so the total flash is lower than a full cascade gives. For fewer stages, read the first outputs only.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- condensates and Table 32.8
- pp. 516–520
- Saturation enthalpies from IAPWS-IF97
Questions and answers
Where does the flash vapour go?
Into the steam chest of the next vessel, where it heats juice like any other vapour.
Is it worth piping?
Hugot finds about 4–5 % more evaporation from a quadruple.
Exhaust condensate?
It returns to the boilers; flash it only into a vessel if the boiler feed temperature allows.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.