Evaporator Condensate Flash Cascade

Vapour flashed from condensate passing from one calandria to the next colder one, stage by stage through four more calandrias, with IF97 enthalpies (Hugot ch. 32).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Quadruple 120/111/100/85/55Exhaust condensate to 3 effects

Results

Hugot: flashing condensates from vessel to vessel raises the evaporation of a quadruple by about 4.6 %.

Only the first calandria's condensate is followed; in a full cascade each later calandria's own condensate joins it and flashes too, so the real total is higher.

Vapour flashed into calandria 2377.50kg/h
Vapour flashed into calandria 3400.77kg/h
Vapour flashed into calandria 4455.71kg/h
Vapour flashed into calandria 50kg/h
Total vapour flashed1,234.0kg/h
Condensate left at the end18,766kg/h
Share flashed6.1699%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Quadruple 120/111/100/85/55. The inputs, in the units selected above:

InputValue
Condensate leaving the first calandria30,000 kg/h
Temperature of that condensate120.00 °C
Temperature of calandria 2111.00 °C
Temperature of calandria 3100.00 °C
Temperature of calandria 485.000 °C
Temperature of calandria 555.000 °C

Applying the formula below gives:

ResultValue
Vapour flashed into calandria 2514.42 kg/h
Vapour flashed into calandria 3607.61 kg/h
Vapour flashed into calandria 4794.52 kg/h
Vapour flashed into calandria 51,489.6 kg/h
Total vapour flashed3,406.2 kg/h
Condensate left at the end26,594 kg/h
Share flashed11.354 %

Open this example in the calculator and change any input.

Formula

\(F_i = \dot m_{L,i-1}\frac{h_f(T_{i-1}) - h_f(T_i)}{h_g(T_i) - h_f(T_i)}, \quad \dot m_{L,i} = \dot m_{L,i-1} - F_i\)

Variables

Symbol Meaning SI unit
\(\dot m_c\) Condensate leaving the first calandria kg/s
\(T_0\) Temperature of that condensate K
\(T_1\) Temperature of calandria 2 K
\(T_2\) Temperature of calandria 3 K
\(T_3\) Temperature of calandria 4 K
\(T_4\) Temperature of calandria 5 K
\(F_1\) Vapour flashed into calandria 2 kg/s
\(F_2\) Vapour flashed into calandria 3 kg/s
\(F_3\) Vapour flashed into calandria 4 kg/s
\(F_4\) Vapour flashed into calandria 5 kg/s
\(\Sigma F\) Total vapour flashed kg/s
\(\dot m_L\) Condensate left at the end kg/s
\(\Sigma F/\dot m_c\) Share flashed -

Method and standards

Adiabatic flash with IF97.

Where it is used

  • Evaporator steam economy.
  • Condensate system design.

Common mistakes

  • Flashing condensate into a hotter vessel.
  • Mixing condensates of different temperatures without a balance.

Assumptions and limits

  • Saturated condensate; no heat loss.
  • Only the condensate leaving the first calandria is followed through four stages. Each later calandria's own condensate, which joins the cascade in Hugot's scheme, is not added, so the total flash is lower than a full cascade gives. For fewer stages, read the first outputs only.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • condensates and Table 32.8
  • pp. 516–520
  • Saturation enthalpies from IAPWS-IF97

Questions and answers

Where does the flash vapour go?

Into the steam chest of the next vessel, where it heats juice like any other vapour.

Is it worth piping?

Hugot finds about 4–5 % more evaporation from a quadruple.

Exhaust condensate?

It returns to the boilers; flash it only into a vessel if the boiler feed temperature allows.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.