FireCADCalc

Entrainment Separator: Allowable Vapour Velocity (Souders–Brown)

Allowable vapour velocity, area and diameter of a vapour space or entrainment separator from the Souders–Brown coefficient, vapour flow and densities (IF97 vapour).

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Last body 16 kPaFirst body 1.6 bar

From the separator maker or your practice.

Results

Sugar in the condenser water is lost sugar: check entrainment by testing tail water.

Vapour density (saturated)0.10603kg/m³
Allowable vapour velocity6.5142m/s
Vapour space area8.0430m²
Diameter3.2001m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Last body 16 kPa. The inputs, in the units selected above:

InputValue
Vapour flow20.000 t/h
Vapour pressure (absolute)16.000 kPa
Liquid (juice or syrup) density1,250.0 kg/m³
Souders–Brown coefficient0.060000 m/s

Applying the formula below gives:

ResultValue
Vapour density (saturated)0.10603 kg/m³
Allowable vapour velocity6.5142 m/s
Vapour space area8.0430 m²
Diameter3.2001 m

Open this example in the calculator and change any input.

Formula

\(v_{max} = K\sqrt{\frac{\rho_l - \rho_v}{\rho_v}}, \quad A = \frac{\dot m_v}{\rho_v v_{max}}\)

Variables

Symbol Meaning SI unit
\(\dot m_v\) Vapour flow kg/s
\(p\) Vapour pressure (absolute) Pa
\(\rho_l\) Liquid (juice or syrup) density kg/m³
\(K\) Souders–Brown coefficient m/s
\(\rho_v\) Vapour density (saturated) kg/m³
\(v_{max}\) Allowable vapour velocity m/s
\(A\) Vapour space area m²
\(D\) Diameter m

Method and standards

Souders–Brown.

Where it is used

  • Evaporator last body and pan vapour space.
  • Entrainment troubleshooting.

Common mistakes

  • K from a different separator type.

Assumptions and limits

  • Saturated vapour.
  • The default K of 0.06 m/s is a starting value with no particular source: the velocity and area scale directly with K, so use the separator maker's figure or your plant practice.

References

  • Souders and Brown (1934) v = K √((ρ_l − ρ_v)/ρ_v); vapour density from IAPWS-IF97

Questions and answers

Why does low pressure need large bodies?

Vapour density falls with pressure, so velocity limits demand more area.

What K?

Plain vapour spaces use low K; mesh or vane separators allow more: use the maker's figure.

How is entrainment found?

Sugar in condensate or condenser water tested with alpha-naphthol or conductivity.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.