Worked example
Example: Last body 16 kPa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour flow | 20.000 t/h |
| Vapour pressure (absolute) | 16.000 kPa |
| Liquid (juice or syrup) density | 1,250.0 kg/m³ |
| Souders–Brown coefficient | 0.060000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour density (saturated) | 0.10603 kg/m³ |
| Allowable vapour velocity | 6.5142 m/s |
| Vapour space area | 8.0430 m² |
| Diameter | 3.2001 m |
Open this example in the calculator and change any input.
Formula
\(v_{max} = K\sqrt{\frac{\rho_l - \rho_v}{\rho_v}}, \quad A = \frac{\dot m_v}{\rho_v v_{max}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_v\) | Vapour flow | kg/s |
| \(p\) | Vapour pressure (absolute) | Pa |
| \(\rho_l\) | Liquid (juice or syrup) density | kg/m³ |
| \(K\) | Souders–Brown coefficient | m/s |
| \(\rho_v\) | Vapour density (saturated) | kg/m³ |
| \(v_{max}\) | Allowable vapour velocity | m/s |
| \(A\) | Vapour space area | m² |
| \(D\) | Diameter | m |
Method and standards
Souders–Brown.
Where it is used
- Evaporator last body and pan vapour space.
- Entrainment troubleshooting.
Common mistakes
- K from a different separator type.
Assumptions and limits
- Saturated vapour.
- The default K of 0.06 m/s is a starting value with no particular source: the velocity and area scale directly with K, so use the separator maker's figure or your plant practice.
References
- Souders and Brown (1934) v = K √((ρ_l − ρ_v)/ρ_v); vapour density from IAPWS-IF97
Questions and answers
Why does low pressure need large bodies?
Vapour density falls with pressure, so velocity limits demand more area.
What K?
Plain vapour spaces use low K; mesh or vane separators allow more: use the maker's figure.
How is entrainment found?
Sugar in condensate or condenser water tested with alpha-naphthol or conductivity.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.