FireCADCalc

Juice Heater Heating Surface (LMTD)

Heating surface of a condensing-steam juice heater from the duty, the overall coefficient and the log-mean temperature difference to steam.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Raw juice heaterClear juice heater

Results

U falls as scale builds: size with a fouled coefficient and clean on a schedule.

Steam saturation temperature120.21°C
Log-mean temperature difference42.512K
Heating surface450.46m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Raw juice heater. The inputs, in the units selected above:

InputValue
Heater duty19,150 kW
Heating steam pressure (absolute)2.0000 bar
Juice in35.000 °C
Juice out103.00 °C
Overall heat-transfer coefficient1,000.0 W/(m²·K)

Applying the formula below gives:

ResultValue
Steam saturation temperature120.21 °C
Log-mean temperature difference42.512 K
Heating surface450.46 m²

Open this example in the calculator and change any input.

Formula

\(\Delta T_{lm} = \frac{T_2 - T_1}{\ln\frac{T_s - T_1}{T_s - T_2}}, \quad A = \frac{\dot Q}{U \Delta T_{lm}}\)

Variables

Symbol Meaning SI unit
\(\dot Q\) Heater duty W
\(p_s\) Heating steam pressure (absolute) Pa
\(T_1\) Juice in K
\(T_2\) Juice out K
\(U\) Overall heat-transfer coefficient W/(m²·K)
\(T_s\) Steam saturation temperature K
\(\Delta T_{lm}\) Log-mean temperature difference K
\(A\) Heating surface m²

Method and standards

LMTD with a condensing side.

Where it is used

  • Juice heater sizing and checks.

Common mistakes

  • Clean U for design.

Assumptions and limits

  • Condensing steam at constant temperature.
  • U and A must be on the same tube area basis; Hugot uses the inside area of the tubes.
  • The steam pressure is absolute: a gauge reading entered as absolute understates T_s by about 20 K at 1 bar(g).

References

  • Q = U A ΔT_lm with condensing steam (Incropera); T_sat from IAPWS-IF97; U from Hugot or plant data

Questions and answers

What U to use?

Plant tests or Hugot's figures for the juice velocity and the steam; a fouled value for sizing.

Why does the outlet approach the steam temperature slowly?

LMTD shrinks as the approach closes, so the last degrees cost much surface.

Several heaters in series?

Calculate each stage with its own steam or vapour.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators