Worked example
Example: Raw juice heater. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heater duty | 19,150 kW |
| Heating steam pressure (absolute) | 2.0000 bar |
| Juice in | 35.000 °C |
| Juice out | 103.00 °C |
| Overall heat-transfer coefficient | 1,000.0 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam saturation temperature | 120.21 °C |
| Log-mean temperature difference | 42.512 K |
| Heating surface | 450.46 m² |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{lm} = \frac{T_2 - T_1}{\ln\frac{T_s - T_1}{T_s - T_2}}, \quad A = \frac{\dot Q}{U \Delta T_{lm}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot Q\) | Heater duty | W |
| \(p_s\) | Heating steam pressure (absolute) | Pa |
| \(T_1\) | Juice in | K |
| \(T_2\) | Juice out | K |
| \(U\) | Overall heat-transfer coefficient | W/(m²·K) |
| \(T_s\) | Steam saturation temperature | K |
| \(\Delta T_{lm}\) | Log-mean temperature difference | K |
| \(A\) | Heating surface | m² |
Method and standards
LMTD with a condensing side.
Where it is used
- Juice heater sizing and checks.
Common mistakes
- Clean U for design.
Assumptions and limits
- Condensing steam at constant temperature.
- U and A must be on the same tube area basis; Hugot uses the inside area of the tubes.
- The steam pressure is absolute: a gauge reading entered as absolute understates T_s by about 20 K at 1 bar(g).
References
- Q = U A ΔT_lm with condensing steam (Incropera); T_sat from IAPWS-IF97; U from Hugot or plant data
Questions and answers
What U to use?
Plant tests or Hugot's figures for the juice velocity and the steam; a fouled value for sizing.
Why does the outlet approach the steam temperature slowly?
LMTD shrinks as the approach closes, so the last degrees cost much surface.
Several heaters in series?
Calculate each stage with its own steam or vapour.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.