FireCADCalc

Compressor Settle-Out Pressure after Shutdown

Pressure reached when the suction and discharge sides of a compressor loop equalise after a trip, from their volumes, pressures and temperatures.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 30 m3 at 20 bar + 15 m3 at 60 barSmall discharge volume 5 m3Refrigeration loop 2 m3/1 m3

Accepted: 0.001 to 100,000 m³
Accepted: 0.01 to 50 MPa
Accepted: -73.15 to 326.85 °C
Accepted: 0.001 to 100,000 m³
Accepted: 0.01 to 50 MPa
Accepted: -73.15 to 426.85 °C

Results

Ideal gas, adiabatic mixing with constant c_v: moles add and the mixed temperature is the mole-weighted mean, so p_so = (p_sV_s + p_dV_d)/(V_s + V_d). Real settle-out analysis uses the gas's equation of state and cooler heat; the suction side and the compressor casing must be rated for p_so.

Settle-out pressure0.70000MPa
Mixed gas temperature (ideal gas, constant c_v)48.523°C
Gas in the loop (kmol)0.78518

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 30 m3 at 20 bar + 15 m3 at 60 bar. The inputs, in the units selected above:

InputValue
Suction-side volume30.000 m³
Suction pressure (absolute)2.0000 MPa
Suction-side gas temperature30.000 °C
Discharge-side volume (to the check valve)15.000 m³
Discharge pressure (absolute)6.0000 MPa
Discharge-side gas temperature60.000 °C

Applying the formula below gives:

ResultValue
Settle-out pressure3.3333 MPa
Mixed gas temperature (ideal gas, constant c_v)47.315 °C
Gas in the loop (kmol)56.296

Open this example in the calculator and change any input.

Formula

\(p_{so} = \frac{p_sV_s + p_dV_d}{V_s + V_d}\;\;(\text{ideal gas, adiabatic mixing})\)

Variables

Symbol Meaning SI unit
\(V_s\) Suction-side volume m³
\(p_s\) Suction pressure (absolute) Pa
\(T_s\) Suction-side gas temperature K
\(V_d\) Discharge-side volume (to the check valve) m³
\(p_d\) Discharge pressure (absolute) Pa
\(T_d\) Discharge-side gas temperature K
\(p_{so}\) Settle-out pressure Pa
\(T_{so}\) Mixed gas temperature (ideal gas, constant c_v) K
\(n\) Gas in the loop (kmol) -

Method and standards

Settle-out balance.

Where it is used

  • Compressor station design pressures.
  • Relief valve sizing basis.

Common mistakes

  • Using the discharge pressure as suction design pressure without checking.
  • Ignoring cooler volumes.

Assumptions and limits

  • Ideal gas; adiabatic; equal heat capacities.

References

  • Ideal-gas settle-out balance

Questions and answers

Why does settle-out pressure matter?

After a trip, high-pressure discharge gas leaks back to the suction side; suction piping, scrubbers and seals must withstand the settled pressure or have relief.

How can it be reduced?

Keep discharge-side volume small by placing check valves close to the compressor, or blow down part of the loop.

What do the defaults represent?

An illustrative loop with 30 m³ at 20 bar and 30 °C on suction and 15 m³ at 60 bar and 60 °C on discharge.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Brown, Compressors: Selection and Sizing, 3rd ed. (Gulf Professional, 2005)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.