FireCADCalc

Polymer Time–Temperature Shift (WLF Equation)

Shift factor between a reference temperature (often T_g) and another temperature for a polymer by the Williams–Landel–Ferry equation, and the equivalent time.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: T_g 80 °C, used at 100 °C, 1,000 hT_g 105 °C, 150 °C, 10 h

Results

WLF holds from about T_g to T_g + 100 K for amorphous polymers; below T_g use an Arrhenius shift.

log₁₀ of shift factor-4.8715
Shift factor1.3443e-05
Equivalent time at T0.013443h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: T_g 80 °C, used at 100 °C, 1,000 h. The inputs, in the units selected above:

InputValue
Temperature of interest100.00 °C
Reference temperature (T_g for universal constants)80.000 °C
WLF constant C₁17.440 -
WLF constant C₂51.600 K
Time at the reference temperature1,000.0 h

Applying the formula below gives:

ResultValue
log₁₀ of shift factor-4.8715
Shift factor1.3443e-05
Equivalent time at T0.013443 h

Open this example in the calculator and change any input.

Formula

\(\log_{10}a_T = \frac{-C_1(T - T_r)}{C_2 + T - T_r}, \quad t_T = a_Tt_r\)

Variables

Symbol Meaning SI unit
\(T\) Temperature of interest K
\(T_r\) Reference temperature (T_g for universal constants) K
\(C_1\) WLF constant C₁ -
\(C_2\) WLF constant C₂ K
\(t_r\) Time at the reference temperature s
\(\log_{10}a_T\) log₁₀ of shift factor -
\(a_T\) Shift factor -
\(t_T\) Equivalent time at T s

Method and standards

WLF equation.

Where it is used

  • Polymer creep and relaxation prediction.
  • Accelerated testing of seals and liners.

Common mistakes

  • Using WLF below T_g.
  • Using universal constants with a reference other than T_g.

Assumptions and limits

  • Amorphous polymers above T_g.

References

  • Williams
  • Landel and Ferry (1955)
  • J. Am. Chem. Soc. 77: 3701 (universal constants C₁ = 17.44, C₂ = 51.6 K at T_g)

Questions and answers

What does a_T mean?

How much faster (a_T < 1) or slower relaxation and creep run at T compared with the reference temperature.

Why is it useful?

Short tests at higher temperature predict long-time behaviour at lower temperature (time–temperature superposition).

What do the defaults represent?

An amorphous polymer with T_g = 80 °C used at 100 °C, with 1,000 h of reference-temperature behaviour.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.