Worked example
Example: 10 m of steel, 20 to 300 °C, 1 m³. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial length | 10.000 m |
| Linear expansion coefficient | 12.000 µm/(m·K) |
| Initial temperature | 20.000 °C |
| Final temperature | 300.00 °C |
| Initial volume (for the volume change) | 1.0000 m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Change in length α L₀ ΔT | 33.600 mm |
| Final length | 10.034 m |
| Volume coefficient 3α | 36.000 µm/(m·K) |
| Change in volume | 0.010080 m³ |
| Relative change in area 2α ΔT | 0.67200 % |
Open this example in the calculator and change any input.
Formula
\(\Delta L = \alpha L_0 \Delta T, \quad \beta \approx 3\alpha, \quad \Delta V = \beta V_0 \Delta T\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_0\) | Initial length | m |
| \(\alpha\) | Linear expansion coefficient | 1/K |
| \(T_1\) | Initial temperature | K |
| \(T_2\) | Final temperature | K |
| \(V_0\) | Initial volume (for the volume change) | m³ |
| \(\Delta L\) | Change in length α L₀ ΔT | m |
| \(L\) | Final length | m |
| \(\beta\) | Volume coefficient 3α | 1/K |
| \(\Delta V\) | Change in volume | m³ |
| \(\Delta A/A\) | Relative change in area 2α ΔT | - |
Method and standards
Linear expansion.
Where it is used
- Pipework, rails and structures.
- Fits and clearances.
Common mistakes
- Instantaneous α for a wide range.
- °C vs K confusion (differences are equal).
Assumptions and limits
- Isotropic solid.
References
- Linear thermal expansion ΔL = α L₀ ΔT (small strain)
Questions and answers
How much does 10 m of steel grow from 20 to 300 °C?
33.6 mm.
Why is volume 3α?
Each of three dimensions grows by α ΔT; second-order terms are negligible.
Which α?
The mean coefficient over the temperature range, from the material data.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.