FireCADCalc

Elastomer Modulus from Shore A Hardness

Young's modulus and shear modulus of a rubber or elastomer estimated from its Shore A durometer hardness by Gent's relation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 60 Shore A80 Shore A

Results

Gent's relation for incompressible rubber; accuracy is about ±20 % and depends on filler and test time.

Young's modulus9.3514MPa
Shear modulus3.1171MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 Shore A. The inputs, in the units selected above:

InputValue
Shore A hardness60.000 -

Applying the formula below gives:

ResultValue
Young's modulus3.6051 MPa
Shear modulus1.2017 MPa

Open this example in the calculator and change any input.

Formula

\(E = \frac{0.0981(56 + 7.62336S_A)}{0.137505(254 - 2.54S_A)}\ \mathrm{MPa}\)

Variables

Symbol Meaning SI unit
\(S_A\) Shore A hardness -
\(E\) Young's modulus Pa
\(G\) Shear modulus Pa

Method and standards

Gent's relation.

Where it is used

  • Anti-vibration mounts.
  • Coupling and seal stiffness.

Common mistakes

  • Using Shore D values.
  • Expecting better than ±20 %.

Assumptions and limits

  • Incompressible rubber; 40–90 Shore A.

References

  • Gent (1958)
  • Trans. Inst. Rubber Ind. 34: 46 (E from the indentation of the durometer spring)

Questions and answers

Why is G = E/3?

Rubber is nearly incompressible (Poisson's ratio about 0.5).

Where is it used?

Sizing rubber mounts, couplings and gaskets when only the hardness is known.

What do the defaults represent?

A 60 Shore A rubber.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.