FireCADCalc

Larson–Miller Parameter: Creep Life and Temperature

Larson–Miller parameter from a temperature and time to rupture, the equivalent life at another temperature, and the temperature for a target creep life.

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalBoiler

Inputs

Examples: 100 000 h at 550 °C; life at 575 °C; temperature for 200 000 hSuperheater tube 30 000 h at 600 °C, C 20; at 580 °C; for 100 000 hTest 1 000 h at 650 °C, C 22; at 540 °C; for 250 000 h

About 20 for most steels; fitted from creep data for a particular alloy.

Results

Same stress at both temperatures; for remaining-life decisions use the material's creep-rupture data and an inspection-based assessment.

Larson–Miller parameter (K, time in hours)23,079
Equivalent life at T₂ (same stress)2,409,405h
Temperature for the target life (same stress)569.20°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 000 h at 550 °C; life at 575 °C; temperature for 200 000 h. The inputs, in the units selected above:

InputValue
Temperature of the known life550.00 °C
Known time to rupture at T₁100,000 h
Larson–Miller constant20.000 -
Another temperature575.00 °C
Target life200,000 h

Applying the formula below gives:

ResultValue
Larson–Miller parameter (K, time in hours)20,579
Equivalent life at T₂ (same stress)18,327 h
Temperature for the target life (same stress)540.21 °C

Open this example in the calculator and change any input.

Formula

\(LMP = T (C + \log_{10} t_h)\)

\(t_2 = 10^{LMP / T_2 - C}\)

\(T_3 = \frac{LMP}{C + \log_{10} t_3}\)

Variables

Symbol Meaning SI unit
\(T_1\) temperature of the known life K
\(t_1\) known time to rupture s
\(C\) Larson–Miller constant -
\(T_2\) another temperature K
\(t_3\) target life s
\(t_h\) time in hours h
\(T\) absolute temperature K
\(LMP\) Larson–Miller parameter K
\(t_2\) equivalent life at T₂ s
\(T_3\) temperature for the target life K

Method and standards

The Larson–Miller parameter combines temperature and time to rupture at a given stress into one number: at constant stress, all combinations with the same LMP give rupture.

Where it is used

  • Judging the effect of overheating on superheater and reheater tubes.
  • Comparing operating temperatures for life.
  • Accelerated creep test planning.

Common mistakes

  • Using °C instead of kelvin.
  • Using time in seconds instead of hours.
  • Comparing at different stresses.

Assumptions and limits

  • Same stress; C from material data; no oxidation or wall thinning.
  • Stress is not an input and no safety factor is applied: the results compare temperature and time at one stress. They are not a remaining-life assessment of boiler tubes, which needs the material's creep-rupture data at the actual stress, wall thickness measurements and inspection.

References

  • Larson and Miller (1952)

Questions and answers

If a tube lasts 100 000 h at 550 °C, how long at 575 °C at the same stress?

About 18 300 h with C = 20: a 25 K rise cuts creep life by about 80 %.

What temperature gives 200 000 h?

About 540 °C in the same example.

What constant C should I use?

About 20 for many steels; fit it to creep-rupture data for the specific alloy where available.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.