FireCADCalc

Bulk Density and Porosity by Archimedes' Method

Bulk density, open porosity, water absorption and total porosity of a refractory or ceramic from dry, saturated and suspended masses.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Refractory brick sampleInsulating castable

Results

Boil or vacuum-saturate the specimen so open pores fill. Closed porosity = total − apparent porosity.

Bulk density1,134.1kg/m³
Apparent (open) porosity50.000%
Water absorption44.000%
Apparent solid density2,268.2kg/m³
Total porosity60.893%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Refractory brick sample. The inputs, in the units selected above:

InputValue
Dry mass100.00 g
Saturated mass (in air)108.00 g
Suspended mass (in water)62.000 g
Water density998.00 kg/m³
True (solid) density2,700.0 kg/m³

Applying the formula below gives:

ResultValue
Bulk density2,169.6 kg/m³
Apparent (open) porosity17.391 %
Water absorption8.0000 %
Apparent solid density2,626.3 kg/m³
Total porosity19.646 %

Open this example in the calculator and change any input.

Formula

\(\rho_b = \frac{m_d\rho_w}{m_s - m_i}, \quad P_a = \frac{m_s - m_d}{m_s - m_i}, \quad WA = \frac{m_s - m_d}{m_d}, \quad P_t = 1 - \frac{\rho_b}{\rho_t}\)

Variables

Symbol Meaning SI unit
\(m_d\) Dry mass kg
\(m_s\) Saturated mass (in air) kg
\(m_i\) Suspended mass (in water) kg
\(\rho_w\) Water density kg/m³
\(\rho_t\) True (solid) density kg/m³
\(\rho_b\) Bulk density kg/m³
\(P_a\) Apparent (open) porosity -
\(WA\) Water absorption -
\(\rho_a\) Apparent solid density kg/m³
\(P_t\) Total porosity -

Method and standards

Archimedes' principle: the loss of mass in water gives the bulk volume of the saturated specimen; open porosity is the water taken up over that volume, and total porosity compares the bulk density with the true (solid) density.

Where it is used

  • Refractory and castable quality checks.
  • Sintered and ceramic parts.

Common mistakes

  • Incomplete saturation.
  • Surface water left on the saturated sample.

Assumptions and limits

  • Open pores fully filled.
  • The true density must be at least the bulk density; otherwise the total porosity is not shown.

References

  • Archimedes' principle as in ASTM C20 and ISO 5017 (refractories)

Questions and answers

Why weigh in water?

The buoyant loss of mass gives the volume; saturation fills open pores so they count in the bulk volume.

What is closed porosity?

Pores not reached by water; the difference between total and apparent porosity.

What do the defaults represent?

A refractory brick sample weighed dry, saturated and suspended.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.