Worked example
Example: Refractory brick sample. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry mass | 100.00 g |
| Saturated mass (in air) | 108.00 g |
| Suspended mass (in water) | 62.000 g |
| Water density | 998.00 kg/m³ |
| True (solid) density | 2,700.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bulk density | 2,169.6 kg/m³ |
| Apparent (open) porosity | 17.391 % |
| Water absorption | 8.0000 % |
| Apparent solid density | 2,626.3 kg/m³ |
| Total porosity | 19.646 % |
Open this example in the calculator and change any input.
Formula
\(\rho_b = \frac{m_d\rho_w}{m_s - m_i}, \quad P_a = \frac{m_s - m_d}{m_s - m_i}, \quad WA = \frac{m_s - m_d}{m_d}, \quad P_t = 1 - \frac{\rho_b}{\rho_t}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_d\) | Dry mass | kg |
| \(m_s\) | Saturated mass (in air) | kg |
| \(m_i\) | Suspended mass (in water) | kg |
| \(\rho_w\) | Water density | kg/m³ |
| \(\rho_t\) | True (solid) density | kg/m³ |
| \(\rho_b\) | Bulk density | kg/m³ |
| \(P_a\) | Apparent (open) porosity | - |
| \(WA\) | Water absorption | - |
| \(\rho_a\) | Apparent solid density | kg/m³ |
| \(P_t\) | Total porosity | - |
Method and standards
Archimedes' principle: the loss of mass in water gives the bulk volume of the saturated specimen; open porosity is the water taken up over that volume, and total porosity compares the bulk density with the true (solid) density.
Where it is used
- Refractory and castable quality checks.
- Sintered and ceramic parts.
Common mistakes
- Incomplete saturation.
- Surface water left on the saturated sample.
Assumptions and limits
- Open pores fully filled.
- The true density must be at least the bulk density; otherwise the total porosity is not shown.
References
- Archimedes' principle as in ASTM C20 and ISO 5017 (refractories)
Questions and answers
Why weigh in water?
The buoyant loss of mass gives the volume; saturation fills open pores so they count in the bulk volume.
What is closed porosity?
Pores not reached by water; the difference between total and apparent porosity.
What do the defaults represent?
A refractory brick sample weighed dry, saturated and suspended.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.