FireCADCalc

Water Stability Lines and Metal Equilibrium Potential

Hydrogen and oxygen equilibrium potentials of water at a pH and temperature, and a metal's equilibrium potential at a chosen ion activity (immunity boundary).

Inputs

Examples: Illustrative water pH 7 with ironAcid pH 2 with zincAlkaline pH 11 at 60 C with copper

Accepted: -2 to 16
Accepted: 0 to 100 °C
Accepted: 1E-6 to 100
Accepted: 1E-6 to 100
Accepted: -3,000 to 2,000 mV
Accepted: 1 to 4
Accepted: 1E-12 to 1

Results

Potentials vs SHE. Water is stable between the hydrogen line 2H⁺ + 2e⁻ ⇌ H₂ (E = −0.0592pH − 0.0296 log p_H₂ at 25 °C) and the oxygen line O₂ + 4H⁺ + 4e⁻ ⇌ 2H₂O (E = 1.229 − 0.0592pH + 0.0148 log p_O₂). A metal is taken as immune below E = E⁰ + (0.0592/z)log a with a = 10⁻⁶. If that potential lies below the hydrogen line the metal can corrode with hydrogen evolution even without oxygen. The water lines' E⁰ is kept at its 25 °C value; only the slope follows temperature. Passivity by oxides needs the full potential–pH diagram.

Hydrogen line (below: water reduced)-118.32mV
Oxygen line (above: water oxidised)1,100.7mV
Metal equilibrium potential (immunity below)-939.48mV
Metal above the hydrogen line (corrodes with H⁺ evolution if > 0)-821.16mV

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative water pH 7 with iron. The inputs, in the units selected above:

InputValue
pH7.0000 -
Temperature25.000 °C
Hydrogen partial pressure (atm)1.0000 -
Oxygen partial pressure (atm)0.21000 -
Metal standard potential-447.00 mV
Ion charge2.0000 -
Ion activity defining immunity1.0000e-06 -

Applying the formula below gives:

ResultValue
Hydrogen line (below: water reduced)-414.12 mV
Oxygen line (above: water oxidised)804.86 mV
Metal equilibrium potential (immunity below)-624.48 mV
Metal above the hydrogen line (corrodes with H⁺ evolution if > 0)-210.36 mV

Open this example in the calculator and change any input.

Formula

\(E_{H_2} = -0.0592pH - 0.0296\log p_{H_2}, \quad E_{O_2} = 1.229 - 0.0592pH + 0.0148\log p_{O_2}, \quad E_M = E^0 + \frac{0.0592}{z}\log a\)

Variables

Symbol Meaning SI unit
\(pH\) pH -
\(T\) Temperature K
\(p_{H_2}\) Hydrogen partial pressure (atm) -
\(p_{O_2}\) Oxygen partial pressure (atm) -
\(E^0_M\) Metal standard potential V
\(z\) Ion charge -
\(a_{M^{z+}}\) Ion activity defining immunity -
\(E_{H_2}\) Hydrogen line (below: water reduced) V
\(E_{O_2}\) Oxygen line (above: water oxidised) V
\(E_{M}\) Metal equilibrium potential (immunity below) V
\(E_M - E_{H_2}\) Metal above the hydrogen line (corrodes with H⁺ evolution if > 0) V

Method and standards

Potential–pH.

Where it is used

  • Cathodic protection potentials.
  • Teaching Pourbaix diagrams.

Common mistakes

  • Mixing SHE and reference electrode scales.
  • Ignoring oxide passivity regions.

Assumptions and limits

  • Equilibrium thermodynamics; ideal activities; water E⁰ at 25 °C.

References

  • Potential–pH equilibria

Questions and answers

What does 'immunity' mean here?

Below the metal's equilibrium potential for 10⁻⁶ ion activity, the metal is thermodynamically stable and cannot corrode.

Why compare with the hydrogen line?

If the metal's potential is below it, water itself can oxidise the metal, releasing hydrogen.

What do the defaults represent?

Water at pH 7 and 25 °C in air, compared with iron (Fe²⁺, E⁰ −0.447 V) at 10⁻⁶ activity.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Pourbaix, Atlas of Electrochemical Equilibria in Aqueous Solutions (NACE, 1974), Fontana, Corrosion Engineering, 3rd ed. (McGraw-Hill, 1986)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.