Worked example
Example: Illustrative Zn-Cu cell, 0.1 and 0.01. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Standard potential of the anode metal | -0.76300 V |
| Standard potential of the cathode metal | 0.34200 V |
| Electrons transferred | 2.0000 - |
| Anode ion activity | 0.10000 - |
| Cathode ion activity | 0.010000 - |
| Temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Standard cell potential | 1.1050 V |
| Nernst concentration term | -29.580 mV |
| Cell potential | 1.0754 V |
| Free energy change per mol of reaction | -207.52 kJ/mol |
Open this example in the calculator and change any input.
Formula
\(E = E^\circ_c - E^\circ_a - \frac{RT}{nF}\ln\frac{a_a}{a_c}, \quad \Delta G = -nFE\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E^\circ_a\) | Standard potential of the anode metal | V |
| \(E^\circ_c\) | Standard potential of the cathode metal | V |
| \(n\) | Electrons transferred | - |
| \(a_a\) | Anode ion activity | - |
| \(a_c\) | Cathode ion activity | - |
| \(T\) | Temperature | K |
| \(E^\circ\) | Standard cell potential | V |
| \(\Delta E_N\) | Nernst concentration term | V |
| \(E\) | Cell potential | V |
| \(\Delta G\) | Free energy change per mol of reaction | J/mol |
Method and standards
Cell potential.
Where it is used
- Teaching and checking galvanic couples.
- Concentration cell corrosion estimates.
Common mistakes
- Swapping anode and cathode activities.
- Using log₁₀ with the RT/F factor.
Assumptions and limits
- Ideal electrodes; activities known; no junction potential.
References
- Nernst equation
Questions and answers
Does a positive cell potential mean fast corrosion?
It means corrosion can occur; the rate depends on polarisation, resistance and the cathode-to-anode area ratio.
Why do standard potentials mislead in seawater?
Passive films and complexing change real potentials; stainless steel, for example, sits much nobler than its standard potential suggests.
What do the defaults represent?
An illustrative zinc–copper cell (−0.763 and +0.342 V) with 0.1 Zn²⁺ and 0.01 Cu²⁺ activity at 25 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Jones, Principles and Prevention of Corrosion, 2nd ed. (Prentice Hall, 1996), Revie and Uhlig, Corrosion and Corrosion Control, 4th ed. (Wiley, 2008)