FireCADCalc

Galvanic Corrosion Rate from Cathode-to-Anode Area Ratio

Anode current density and corrosion penetration rate of a galvanic couple from the cathode reaction rate, the cathode-to-anode area ratio and Faraday's law.

Inputs

Examples: Illustrative steel in copper, 100 to 1Aluminium rivets in stainless sheetLarge anode, benign 1 to 10

Accepted: 1E-10 to 0.0001 A/mm²
Accepted: 1E-6 to 10,000 m²
Accepted: 1E-6 to 10,000 m²
Accepted: 1 to 300 kg/kmol
Accepted: 1 to 4
Accepted: 500 to 25,000 kg/m³

Results

Total anodic current equals total cathodic current. With the cathode reaction (often oxygen reduction, limited by diffusion) proceeding at i_c over the noble area, the anode carries I/A_a, so its attack rate scales with A_c/A_a. Penetration rate = i_aM/(nFρ). Small anodes in large cathodes (steel rivets in copper sheet) fail fast; the reverse is benign. Assumes the whole cathode is effective; in poorly conducting water only nearby areas count.

Area ratio100.00
Galvanic current0.50000A
Anode current density50.000A/m²
Anode penetration rate58.022mm/a
Rate with equal areas0.58022mm/a

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative steel in copper, 100 to 1. The inputs, in the units selected above:

InputValue
Cathodic current density on the noble metal5.0000e-07 A/mm²
Cathode (noble metal) area1.0000 m²
Anode (active metal) area0.010000 m²
Anode molar mass55.845 kg/kmol
Electrons per atom2.0000 -
Anode density7,870.0 kg/m³

Applying the formula below gives:

ResultValue
Area ratio100.00
Galvanic current0.50000 A
Anode current density50.000 A/m²
Anode penetration rate58.022 mm/a
Rate with equal areas0.58022 mm/a

Open this example in the calculator and change any input.

Formula

\(i_a = i_c\frac{A_c}{A_a}, \quad CR = \frac{i_aM}{nF\rho}\)

Variables

Symbol Meaning SI unit
\(i_c\) Cathodic current density on the noble metal A/m²
\(A_c\) Cathode (noble metal) area m²
\(A_a\) Anode (active metal) area m²
\(M\) Anode molar mass kg/kmol
\(n\) Electrons per atom -
\(\rho\) Anode density kg/m³
\(A_c/A_a\) Area ratio -
\(I\) Galvanic current A
\(i_a\) Anode current density A/m²
\(CR\) Anode penetration rate m/s
\(CR_{1:1}\) Rate with equal areas m/s

Method and standards

Area effect.

Where it is used

  • Fastener and fitting material selection.
  • Explaining failures at dissimilar joints.

Common mistakes

  • Ignoring the area ratio.
  • Painting only the anode.

Assumptions and limits

  • Uniform current over each area; cathode reaction rate known.

References

  • Mixed-potential area effect with Faraday's law

Questions and answers

Why is a small anode so bad?

The whole cathode's reaction is balanced by dissolution of a small area, concentrating the attack.

Why paint the cathode rather than the anode?

Painting the anode leaves small holidays as tiny anodes against a large cathode; painting the cathode cuts the cathodic area.

What do the defaults represent?

An illustrative 1 m² of copper with 0.5 A/m² oxygen reduction coupled to 0.01 m² of steel.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fontana, Corrosion Engineering, 3rd ed. (McGraw-Hill, 1986)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.