Worked example
Example: Illustrative 508 mm line, 10000 ohm m2 coating. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pipe outside diameter | 508.00 mm |
| Wall thickness | 9.5000 mm |
| Steel resistivity | 18.000 µΩ·cm |
| Coating resistance | 10,000 Ω·m² |
| Potential shift at the drain point | 0.60000 V |
| Minimum shift needed | 0.30000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pipe longitudinal resistance | 0.012099 mΩ/m |
| Coating leakage resistance (length basis) | 6,265.9 Ω·m |
| Attenuation constant | 4.3941e-05 1/m |
| Characteristic resistance | 0.27533 Ω |
| Drain current (both directions) | 4.3583 A |
| Protected length each side | 15.774 km |
Open this example in the calculator and change any input.
Formula
\(\alpha = \sqrt{\frac{R_s}{R_L}}, \quad Z_c = \sqrt{R_sR_L}, \quad L_p = \frac{1}{\alpha}\ln\frac{\Delta E_0}{\Delta E_{min}}, \quad I_0 = \frac{2\Delta E_0}{Z_c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Pipe outside diameter | m |
| \(t\) | Wall thickness | m |
| \(\rho_s\) | Steel resistivity | Ω·m |
| \(r_c\) | Coating resistance | Ω·m² |
| \(\Delta E_0\) | Potential shift at the drain point | V |
| \(\Delta E_{min}\) | Minimum shift needed | V |
| \(R_s\) | Pipe longitudinal resistance | Ω/m |
| \(R_L\) | Coating leakage resistance (length basis) | Ω·m |
| \(\alpha\) | Attenuation constant | 1/m |
| \(Z_c\) | Characteristic resistance | Ω |
| \(I_0\) | Drain current (both directions) | A |
| \(L_p\) | Protected length each side | m |
Method and standards
Attenuation.
Where it is used
- Spacing CP stations on buried pipelines.
- Assessing coating deterioration from current demand.
Common mistakes
- Using new-coating resistance for end-of-life design.
- Ignoring insulating flanges and branch lines.
Assumptions and limits
- Long uniform line; uniform coating and soil; potential shifts, not absolute potentials.
References
- Pipeline attenuation (transmission-line) equations
Questions and answers
Why does protection fade along the pipe?
Current leaks through coating holidays as it spreads, and the pipe's own resistance drops the potential.
How does coating quality matter?
A well-coated line has high leakage resistance, so one station protects tens of kilometres; a poor coating needs many.
What do the defaults represent?
An illustrative 508 mm × 9.5 mm steel line with 10,000 Ω·m² coating, 0.6 V shift at the drain point and 0.3 V minimum.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.