FireCADCalc

PV Modules on a Roof: Layout Count and Capacity

Number of PV modules that fit on a rectangular roof plane in portrait and landscape with edge setbacks and gaps, the installed capacity and the roof coverage.

Thermal power plant

Inputs

Examples: Illustrative 12 x 6 m roof, 410 W modulesFlat roof 30 x 15 m, 1 m setbacks, 550 WSmall 5 x 4 m, 400 W

Accepted: 1 to 500 m
Accepted: 1 to 200 m
Accepted: 0 to 5 m
Accepted: 0.5 to 3 m
Accepted: 0.3 to 2 m
Accepted: 0 to 200 mm
Accepted: 0.01 to 1 kW

Results

Rectangular grid inside the setbacks: portrait puts the module length up the slope. Obstructions (vents, chimneys, skylights), shading and structural limits reduce the count; check local fire-access rules for setbacks.

Modules in portrait3.0000
Modules in landscape4.0000
Best count4.0000
Installed capacity (best layout)1.6000kW
Module area over roof area39.055%
Capacity per m² of roof (W)80.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 12 x 6 m roof, 410 W modules. The inputs, in the units selected above:

InputValue
Roof length along the eaves12.000 m
Roof width up the slope6.0000 m
Edge setback (fire and wind zone)0.50000 m
Module length1.7220 m
Module width1.1340 m
Gap between modules20.000 mm
Module rating0.41000 kW

Applying the formula below gives:

ResultValue
Modules in portrait18.000
Modules in landscape24.000
Best count24.000
Installed capacity (best layout)9.8400 kW
Module area over roof area65.092 %
Capacity per m² of roof (W)136.67

Open this example in the calculator and change any input.

Formula

\(n_P = \left\lfloor\frac{L - 2s + g}{b + g}\right\rfloor\left\lfloor\frac{W - 2s + g}{a + g}\right\rfloor, \quad P = nP_m\)

Variables

Symbol Meaning SI unit
\(L\) Roof length along the eaves m
\(W\) Roof width up the slope m
\(s\) Edge setback (fire and wind zone) m
\(a\) Module length m
\(b\) Module width m
\(g\) Gap between modules m
\(P_m\) Module rating W
\(n_P\) Modules in portrait -
\(n_L\) Modules in landscape -
\(n\) Best count -
\(P\) Installed capacity (best layout) W
\(A_m/A_{roof}\) Module area over roof area -
\(P/A_{roof}\) Capacity per m² of roof (W) -

Method and standards

Roof layout count.

Where it is used

  • Rooftop PV quotes and feasibility.
  • Comparing module sizes for a given roof.

Common mistakes

  • Ignoring setbacks and obstructions.
  • Mixing module length and width between orientations.

Assumptions and limits

  • Rectangular unobstructed roof plane.

References

  • Module layout arithmetic

Questions and answers

How much PV fits on a roof?

About 180–220 W per m² of usable roof with modern 400–450 W modules; setbacks and obstructions often remove a quarter of the area.

Portrait or landscape?

Whichever fits more modules; portrait is common on pitched roofs, landscape on low wide areas or to suit rails.

What do the defaults represent?

An illustrative 12 m × 6 m roof plane, 0.5 m setbacks, 1.722 m × 1.134 m modules of 410 W with 20 mm gaps.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.