Worked example
Example: Illustrative: R 24.7 k, gain 100 with 499 ohm, 12 mV, ref 1.65 V. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Internal feedback resistor (each of the two input stages) | 24.700 kΩ |
| Required gain | 100.00 - |
| Chosen gain resistor (0 to use the ideal value) | 499.00 Ω |
| Differential input signal | 12.000 mV |
| Reference pin voltage | 1.6500 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gain resistor for the required gain 2R/(G − 1) | 498.99 Ω |
| Gain with the chosen resistor | 99.998 |
| Output voltage G·V_d + V_ref | 2.8500 V |
| Gain error of the chosen resistor | -0.002004 % |
Open this example in the calculator and change any input.
Formula
\(G = 1 + \frac{2R}{R_G}, \quad R_G = \frac{2R}{G - 1}, \quad V_{out} = G\,V_d + V_{ref}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(R\) | Internal feedback resistor (each of the two input stages) | Ω |
| \(G_{target}\) | Required gain | - |
| \(R_G\) | Chosen gain resistor (0 to use the ideal value) | Ω |
| \(V_d\) | Differential input signal | V |
| \(V_{ref}\) | Reference pin voltage | V |
| \(R_{G,ideal}\) | Gain resistor for the required gain 2R/(G − 1) | Ω |
| \(G\) | Gain with the chosen resistor | - |
| \(V_{out}\) | Output voltage G·V_d + V_ref | V |
| \(\Delta G/G\) | Gain error of the chosen resistor | - |
Method and standards
Instrumentation amplifier relations.
Where it is used
- Strain gauge, load cell and thermocouple amplifiers.
- Medical and data-acquisition front ends.
Common mistakes
- Using a different internal resistor value than the datasheet's.
- Exceeding the input common-mode range at high gain.
Assumptions and limits
- Ideal matched resistors and op-amps.
References
- Three-op-amp instrumentation amplifier
Questions and answers
Why use an instrumentation amplifier for a bridge?
It amplifies only the small difference between two inputs that both sit at half the supply, with high common-mode rejection and high input impedance.
What is the reference pin for?
It shifts the output, for example to mid-supply so a bipolar signal can be read by a single-supply ADC.
What do the defaults represent?
An illustrative in-amp with 24.7 kΩ internal resistors, a gain of 100 (499 Ω chosen), a 12 mV bridge signal and a 1.65 V reference.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 5, Sedra and Smith, Microelectronic Circuits, 7th ed. (Oxford University Press, 2015), ch. 2