Worked example
Example: Illustrative: fast mode, 3.3 V, 150 pF. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bus mode | Fast-mode 400 kHz (t_r ≤ 300 ns) |
| Pull-up supply voltage | 3.3000 V |
| Total bus capacitance | 150.00 pF |
| Maximum low-level output voltage | 0.40000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum pull-up (V_DD − V_OL)/I_OL | 0.96667 kΩ |
| Maximum pull-up t_r/(0.8473 C_b) | 2.3604 kΩ |
| Rise-time limit of the mode | 300.00 ns |
| Sink current of the mode | 3.0000 mA |
| Suggested value (geometric mean) | 1.5106 kΩ |
Open this example in the calculator and change any input.
Formula
\(R_{p,min} = \frac{V_{DD} - V_{OL,max}}{I_{OL}}, \quad R_{p,max} = \frac{t_r}{0.8473\,C_b}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{mode}\) | Bus mode | - |
| \(V_{DD}\) | Pull-up supply voltage | V |
| \(C_b\) | Total bus capacitance | F |
| \(V_{OL}\) | Maximum low-level output voltage | V |
| \(R_{p,min}\) | Minimum pull-up (V_DD − V_OL)/I_OL | Ω |
| \(R_{p,max}\) | Maximum pull-up t_r/(0.8473 C_b) | Ω |
| \(t_r\) | Rise-time limit of the mode | s |
| \(I_{OL}\) | Sink current of the mode | A |
| \(R_{p}\) | Suggested value (geometric mean) | Ω |
Method and standards
Open-drain bus pull-up sizing.
Where it is used
- Microcontroller and sensor boards, I²C and SMBus wiring.
- Long buses and multi-board systems.
Common mistakes
- Adding pull-ups on every board in parallel.
- Underestimating the capacitance of cables and connectors.
Assumptions and limits
- Resistive pull-ups; specification limits for each mode.
References
- Pull-up limits from the I²C bus specification
Questions and answers
Why is 4.7 kΩ so common?
At 3.3–5 V and a typical 100–200 pF bus it lies between the limits for standard mode; fast mode often needs 2.2 kΩ or less.
What sets the maximum value?
The bus capacitance charged through the pull-up must reach the high threshold within the mode's rise-time limit.
What do the defaults represent?
An illustrative fast-mode (400 kHz) bus at 3.3 V with 150 pF of bus capacitance.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
NXP, UM10204 I²C-bus specification and user manual, Rev. 7 (2021), sec. 7.1