FireCADCalc

555 Timer Astable Frequency, Duty Cycle and Monostable Pulse

Frequency, period, high and low times and duty cycle of a 555 timer in astable mode, and the pulse width in monostable mode, from the timing resistors and capacitor.

Inputs

Examples: Illustrative astable: 4.7 k, 47 k, 10 nF1 Hz LED flasher: 10 k, 68 k, 10 uFAudio tone about 1 kHz: 1 k, 6.8 k, 100 nF

Accepted: 0.1 to 100,000 kΩ
Accepted: 0.1 to 100,000 kΩ
Accepted: 1E-6 to 1,000,000 µF

Results

The capacitor charges between ⅓ and ⅔ of the supply: t = RC ln 2 for each half-cycle (0.693RC) and ln 3 (1.1RC) for the monostable. The duty cycle exceeds 50 % unless R_B is bypassed by a diode.

Astable frequency1,461.7Hz
Output high time 0.693(R_A + R_B)C0.35836ms
Output low time 0.693 R_B C0.32578ms
Duty cycle t_H/T52.381%
Monostable pulse width 1.1 R_A C0.051635ms

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative astable: 4.7 k, 47 k, 10 nF. The inputs, in the units selected above:

InputValue
Resistor R_A (VCC to discharge)4.7000 kΩ
Resistor R_B (discharge to threshold)47.000 kΩ
Timing capacitor0.010000 µF

Applying the formula below gives:

ResultValue
Astable frequency1,461.7 Hz
Output high time 0.693(R_A + R_B)C0.35836 ms
Output low time 0.693 R_B C0.32578 ms
Duty cycle t_H/T52.381 %
Monostable pulse width 1.1 R_A C0.051635 ms

Open this example in the calculator and change any input.

Formula

\(t_H = 0.693(R_A + R_B)C, \quad t_L = 0.693R_BC, \quad f = \frac{1.44}{(R_A + 2R_B)C}, \quad t_{mono} = 1.1R_AC\)

Variables

Symbol Meaning SI unit
\(R_A\) Resistor R_A (VCC to discharge) Ω
\(R_B\) Resistor R_B (discharge to threshold) Ω
\(C\) Timing capacitor F
\(f\) Astable frequency 1/s
\(t_H\) Output high time 0.693(R_A + R_B)C s
\(t_L\) Output low time 0.693 R_B C s
\(D\) Duty cycle t_H/T -
\(t_{mono}\) Monostable pulse width 1.1 R_A C s

Method and standards

RC timing of the 555.

Where it is used

  • LED flashers, tone generators and PWM.
  • Timers, debouncing and pulse stretching.

Common mistakes

  • Expecting 50 % duty cycle from the basic circuit.
  • Using an electrolytic capacitor with large leakage for long times.

Assumptions and limits

  • Bipolar 555; ideal thresholds at ⅓ and ⅔ of the supply.

References

  • Charging between one and two thirds of the supply (555 timer)

Questions and answers

Why is the duty cycle always above 50 %?

The capacitor charges through R_A + R_B but discharges through R_B only; a diode across R_B or a different circuit is needed for 50 % or less.

How accurate is the frequency?

Within about 1–5 % with stable components; the capacitor tolerance usually dominates.

What do the defaults represent?

An illustrative astable with R_A = 4.7 kΩ, R_B = 47 kΩ and a 10 nF capacitor.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.