1C discharges the rated capacity in one hour. Real run time is shorter at high rates (Peukert effect, voltage sag) and in the cold; LiPo packs should not be run below about 20 % charge.

Current at the C-rate55.000A
Ideal run time at that C-rate2.4000min
Stored energy24.420Wh
Power at the C-rate610.50W
C-rate of the load current6.8182
Ideal run time at the load current8.8000min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 3S 2200 mAh 25C LiPo, 15 A load. The inputs, in the units selected above:

InputValue
Rated capacity2,200.0 mAh
Nominal voltage11.100 V
C-rate (multiples of capacity per hour)25.000 -
Load current to evaluate15.000 A

Applying the formula below gives:

ResultValue
Current at the C-rate55.000 A
Ideal run time at that C-rate2.4000 min
Stored energy24.420 Wh
Power at the C-rate610.50 W
C-rate of the load current6.8182
Ideal run time at the load current8.8000 min

Open this example in the calculator and change any input.

Formula

\(I = C_{rate}\times C_{Ah}, \quad t = \frac{1}{C_{rate}}\ \text{h}, \quad E = C_{Ah}U, \quad C_{load} = \frac{I_{load}}{C_{Ah}}\)

Variables

Symbol Meaning SI unit
\(C\) Rated capacity C
\(U\) Nominal voltage V
\(C_{rate}\) C-rate (multiples of capacity per hour) -
\(I_{load}\) Load current to evaluate A
\(I\) Current at the C-rate A
\(t\) Ideal run time at that C-rate s
\(E\) Stored energy J
\(P\) Power at the C-rate W
\(C_{load}\) C-rate of the load current -
\(t_{load}\) Ideal run time at the load current s

Method and standards

Battery rate definitions.

Where it is used

  • Battery selection for drones, RC models, tools and EVs.
  • Charger and protection setting.

Common mistakes

  • Confusing milliampere-hours with watt-hours.
  • Running packs at their burst rating continuously.

Assumptions and limits

  • Ideal capacity independent of rate.

References

  • C-rate definition and ideal capacity relations

Questions and answers

What does a 25C rating mean?

The pack can deliver 25 times its capacity in amperes: a 2,200 mAh 25C pack can supply 55 A continuously.

Is the run time at 2C exactly 30 minutes?

No; at high rates the usable capacity falls, so the real time is somewhat shorter (see the Peukert calculator).

What do the defaults represent?

An illustrative 3-cell 2,200 mAh 25C LiPo pack, checked against a 15 A load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Linden and Reddy, Handbook of Batteries, 4th ed. (McGraw-Hill, 2011), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.