Worked example
Example: Illustrative: 5.1 V Zener, 11-14 V supply, 20 mA load, 5 mA minimum. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Minimum input voltage | 11.000 V |
| Maximum input voltage | 14.000 V |
| Zener voltage | 5.1000 V |
| Maximum load current | 20.000 mA |
| Minimum Zener current to stay in regulation | 5.0000 mA |
Applying the formula below gives:
| Result | Value |
|---|---|
| Series resistor (largest that still regulates) | 236.00 Ω |
| Resistor dissipation at maximum input | 0.33564 W |
| Zener current at maximum input and no load | 37.712 mA |
| Zener dissipation at maximum input and no load | 0.19233 W |
| Efficiency at minimum input and full load | 37.091 % |
Open this example in the calculator and change any input.
Formula
\(R_s = \frac{V_{in,min} - V_Z}{I_L + I_{Z,min}}, \quad I_{Z,max} = \frac{V_{in,max} - V_Z}{R_s}, \quad P_Z = V_ZI_{Z,max}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_{in,min}\) | Minimum input voltage | V |
| \(V_{in,max}\) | Maximum input voltage | V |
| \(V_Z\) | Zener voltage | V |
| \(I_L\) | Maximum load current | A |
| \(I_{Z,min}\) | Minimum Zener current to stay in regulation | A |
| \(R_s\) | Series resistor (largest that still regulates) | Ω |
| \(P_R\) | Resistor dissipation at maximum input | W |
| \(I_{Z,max}\) | Zener current at maximum input and no load | A |
| \(P_Z\) | Zener dissipation at maximum input and no load | W |
| \(\eta\) | Efficiency at minimum input and full load | - |
Method and standards
Shunt regulator design.
Where it is used
- Reference voltages and low-current supplies.
- Over-voltage clamps and bias circuits.
Common mistakes
- Sizing the Zener for full-load current only.
- Forgetting the resistor power at maximum input.
Assumptions and limits
- Ideal Zener (zero dynamic resistance).
References
- Zener shunt regulator design
Questions and answers
Why is the worst case at no load?
With the load gone, all the current through R_s flows in the Zener; at maximum input that is its highest dissipation.
When should I use a linear regulator instead?
For more than a few tens of milliamperes, or when the input varies widely; a Zener shunt wastes current at all times.
What do the defaults represent?
An illustrative 5.1 V Zener feeding 20 mA from an 11–14 V supply, with at least 5 mA kept in the Zener.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Sedra and Smith, Microelectronic Circuits, 7th ed. (Oxford University Press, 2015), ch. 4