Rectifier Filter (Reservoir) Capacitor and Ripple

Reservoir capacitor for a half- or full-wave rectifier from load current, mains frequency and allowed ripple, with the peak and mean DC voltages.

Inputs

Examples: Illustrative: 12 V RMS bridge, 1 A, 50 Hz, 1.5 V rippleHalf-wave 9 V, 100 mA, 60 Hz, 1 V rippleAudio amplifier 28 V RMS bridge, 4 A, 50 Hz, 2 V ripple

Accepted: 1 to 1,000 V
Accepted: 0 to 10 V
Accepted: 0.0001 to 100 A
Accepted: 1 to 1,000 Hz
Accepted: 0.001 to 100 V

Results

C = I/(k f ΔV), k = 2 for full-wave, assuming the capacitor supplies the load for the whole ripple period (conservative). Allow for mains low line and transformer regulation; the capacitor's ripple current rating is often the real limit.

Reservoir capacitance6,666.7µF
Peak DC voltage √2 V_s − V_D15.571V
Mean DC voltage V_pk − ΔV/214.821V
Valley voltage V_pk − ΔV14.071V
RMS ripple voltage ΔV/(2√3)0.43301V

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 12 V RMS bridge, 1 A, 50 Hz, 1.5 V ripple. The inputs, in the units selected above:

InputValue
RectifierFull-wave (bridge or centre-tap)
Secondary RMS voltage12.000 V
Total diode drop in the conduction path (bridge: 2 diodes)1.4000 V
Load current1.0000 A
Mains frequency50.000 Hz
Allowed ripple (peak to peak)1.5000 V

Applying the formula below gives:

ResultValue
Reservoir capacitance6,666.7 µF
Peak DC voltage √2 V_s − V_D15.571 V
Mean DC voltage V_pk − ΔV/214.821 V
Valley voltage V_pk − ΔV14.071 V
RMS ripple voltage ΔV/(2√3)0.43301 V

Open this example in the calculator and change any input.

Formula

\(C = \frac{I_{DC}}{k\,f\,\Delta V}\ (k = 2\ \text{full-wave}, 1\ \text{half-wave}), \quad V_{pk} = \sqrt 2V_s - V_D, \quad V_{DC} \approx V_{pk} - \frac{\Delta V}{2}\)

Variables

Symbol Meaning SI unit
\(\text{rectifier}\) Rectifier -
\(V_{s}\) Secondary RMS voltage V
\(V_D\) Total diode drop in the conduction path (bridge: 2 diodes) V
\(I_{DC}\) Load current A
\(f\) Mains frequency 1/s
\(\Delta V\) Allowed ripple (peak to peak) V
\(C\) Reservoir capacitance F
\(V_{pk}\) Peak DC voltage √2 V_s − V_D V
\(V_{DC}\) Mean DC voltage V_pk − ΔV/2 V
\(V_{min}\) Valley voltage V_pk − ΔV V
\(V_{r,rms}\) RMS ripple voltage ΔV/(2√3) V

Method and standards

Capacitor-input filter approximation.

Where it is used

  • Linear power supplies and battery chargers.
  • Input stages of regulators and amplifiers.

Common mistakes

  • Forgetting the diode drops in a bridge.
  • Ignoring low mains voltage when checking the regulator dropout.

Assumptions and limits

  • Constant load current; capacitor discharge treated as linear over the period.

References

  • Capacitor-input rectifier filter

Questions and answers

Why does full-wave need half the capacitance?

The capacitor is recharged twice per mains cycle, so it supplies the load for half as long between peaks.

Is the capacitor current only the load current?

No: it charges in short pulses near the peaks, with RMS ripple currents of two to three times the load current; check the capacitor's ripple rating.

What do the defaults represent?

An illustrative 12 V RMS secondary, bridge rectifier (1.4 V drop), 1 A load on 50 Hz mains with 1.5 V ripple.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.