Worked example
Example: Illustrative: 12 V RMS bridge, 1 A, 50 Hz, 1.5 V ripple. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rectifier | Full-wave (bridge or centre-tap) |
| Secondary RMS voltage | 12.000 V |
| Total diode drop in the conduction path (bridge: 2 diodes) | 1.4000 V |
| Load current | 1.0000 A |
| Mains frequency | 50.000 Hz |
| Allowed ripple (peak to peak) | 1.5000 V |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reservoir capacitance | 6,666.7 µF |
| Peak DC voltage √2 V_s − V_D | 15.571 V |
| Mean DC voltage V_pk − ΔV/2 | 14.821 V |
| Valley voltage V_pk − ΔV | 14.071 V |
| RMS ripple voltage ΔV/(2√3) | 0.43301 V |
Open this example in the calculator and change any input.
Formula
\(C = \frac{I_{DC}}{k\,f\,\Delta V}\ (k = 2\ \text{full-wave}, 1\ \text{half-wave}), \quad V_{pk} = \sqrt 2V_s - V_D, \quad V_{DC} \approx V_{pk} - \frac{\Delta V}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{rectifier}\) | Rectifier | - |
| \(V_{s}\) | Secondary RMS voltage | V |
| \(V_D\) | Total diode drop in the conduction path (bridge: 2 diodes) | V |
| \(I_{DC}\) | Load current | A |
| \(f\) | Mains frequency | 1/s |
| \(\Delta V\) | Allowed ripple (peak to peak) | V |
| \(C\) | Reservoir capacitance | F |
| \(V_{pk}\) | Peak DC voltage √2 V_s − V_D | V |
| \(V_{DC}\) | Mean DC voltage V_pk − ΔV/2 | V |
| \(V_{min}\) | Valley voltage V_pk − ΔV | V |
| \(V_{r,rms}\) | RMS ripple voltage ΔV/(2√3) | V |
Method and standards
Capacitor-input filter approximation.
Where it is used
- Linear power supplies and battery chargers.
- Input stages of regulators and amplifiers.
Common mistakes
- Forgetting the diode drops in a bridge.
- Ignoring low mains voltage when checking the regulator dropout.
Assumptions and limits
- Constant load current; capacitor discharge treated as linear over the period.
References
- Capacitor-input rectifier filter
Questions and answers
Why does full-wave need half the capacitance?
The capacitor is recharged twice per mains cycle, so it supplies the load for half as long between peaks.
Is the capacitor current only the load current?
No: it charges in short pulses near the peaks, with RMS ripple currents of two to three times the load current; check the capacitor's ripple rating.
What do the defaults represent?
An illustrative 12 V RMS secondary, bridge rectifier (1.4 V drop), 1 A load on 50 Hz mains with 1.5 V ripple.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 9