FireCADCalc

Heat Sink Thermal Resistance Required for a Semiconductor

Heat-sink-to-air thermal resistance needed to keep a semiconductor junction below its limit, from power, ambient, junction-to-case and interface resistances.

Inputs

Examples: Illustrative: 15 W, R_JC 1.5, interface 0.5 K/W, 125 C limit, 50 C airLM317 in TO-220: 3.5 W, R_JC 5, 40 CIGBT module 120 W, R_JC 0.25, interface 0.1, 45 C

Accepted: 0.01 to 100,000 W
Accepted: 26.85 to 226.85 °C
Accepted: -43.15 to 126.85 °C
Accepted: 0 to 100
Accepted: 0 to 20
Accepted: 1 to 500

Results

Series thermal path T_j = T_a + P(R_θJC + R_θCS + R_θSA). Choose a heat sink with R_θSA below the result at the expected airflow.

Required heat sink to air resistance (K/W)3.0000
Case temperature at the limit102.50°C
Heat sink temperature at the limit95.000°C
Junction temperature with no heat sink980.00°C
Maximum power with no heat sink1.2097W

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 15 W, R_JC 1.5, interface 0.5 K/W, 125 C limit, 50 C air. The inputs, in the units selected above:

InputValue
Power dissipated15.000 W
Maximum junction temperature (with margin)125.00 °C
Ambient (air inside the enclosure)50.000 °C
Junction-to-case thermal resistance (K/W)1.5000 -
Case-to-sink (interface) thermal resistance (K/W)0.50000 -
Junction-to-ambient without a heat sink (K/W)62.000 -

Applying the formula below gives:

ResultValue
Required heat sink to air resistance (K/W)3.0000
Case temperature at the limit102.50 °C
Heat sink temperature at the limit95.000 °C
Junction temperature with no heat sink980.00 °C
Maximum power with no heat sink1.2097 W

Open this example in the calculator and change any input.

Formula

\(R_{\theta SA} = \frac{T_{j,max} - T_a}{P} - R_{\theta JC} - R_{\theta CS}, \quad T_j = T_a + P(R_{\theta JC} + R_{\theta CS} + R_{\theta SA})\)

Variables

Symbol Meaning SI unit
\(P\) Power dissipated W
\(T_{j,max}\) Maximum junction temperature (with margin) K
\(T_a\) Ambient (air inside the enclosure) K
\(R_{θJC}\) Junction-to-case thermal resistance (K/W) -
\(R_{θCS}\) Case-to-sink (interface) thermal resistance (K/W) -
\(R_{θJA}\) Junction-to-ambient without a heat sink (K/W) -
\(R_{θSA}\) Required heat sink to air resistance (K/W) -
\(T_c\) Case temperature at the limit K
\(T_s\) Heat sink temperature at the limit K
\(T_{j,bare}\) Junction temperature with no heat sink K
\(P_{max,bare}\) Maximum power with no heat sink W

Method and standards

Thermal resistance network.

Where it is used

  • Regulators, MOSFETs, IGBTs and LED modules.
  • Enclosure and fan selection.

Common mistakes

  • Using the room temperature instead of the air inside the enclosure.
  • Ignoring the interface resistance.

Assumptions and limits

  • Steady state, one-dimensional series heat path.

References

  • Series thermal resistance network for semiconductors

Questions and answers

Why use 125 °C instead of the 150 °C rating?

Reliability falls quickly with temperature; designing for 100–125 °C leaves margin for hot spots, tolerances and ageing.

How much does thermal paste help?

A dry metal joint may be 1–2 K/W; a good grease or pad brings it to 0.1–0.5 K/W, often the difference between a small and a large heat sink.

What do the defaults represent?

An illustrative 15 W device with R_θJC 1.5 K/W and a 0.5 K/W interface, kept below 125 °C in 50 °C enclosure air.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Horowitz and Hill, The Art of Electronics, 3rd ed. (Cambridge University Press, 2015), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.