FireCADCalc

Battery Life of a Duty-Cycled Device (Sleep and Active)

Average current and battery life of a sensor or IoT device that wakes periodically, from the active and sleep currents, active time and usable capacity.

Inputs

Examples: Illustrative sensor on 2400 mAhCoin cell beaconCellular meter, hourly

Accepted: 0.27778 to 2,777,800 mAh
Accepted: 10 to 100 %
Accepted: 0 to 10,000 mA
Accepted: 1E-6 to 100,000 s
Accepted: 0 to 1,000 mA
Accepted: 0.001 to 10,000,000 s

Results

The average current is the time-weighted mean of the active and sleep currents; the battery lasts its usable charge divided by that average. With long sleep periods the sleep current often dominates, so a few microamps matter more than shortening the active burst. Self-discharge, cold weather and the device's cut-off voltage reduce usable capacity; the usable share covers them roughly.

Average current0.049653mA
Active share of time0.16667%
Battery life1,611.2d
Battery life in years4.4111
Share of charge used while asleep16.085%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative sensor on 2400 mAh. The inputs, in the units selected above:

InputValue
Battery capacity2,400.0 mAh
Usable share (self-discharge, cut-off and temperature)80.000 %
Current while active25.000 mA
Active time per wake-up0.50000 s
Current while asleep0.008000 mA
Time between wake-ups300.00 s

Applying the formula below gives:

ResultValue
Average current0.049653 mA
Active share of time0.16667 %
Battery life1,611.2 d
Battery life in years4.4111
Share of charge used while asleep16.085 %

Open this example in the calculator and change any input.

Formula

\(\bar I = \frac{I_a t_a + I_s (T - t_a)}{T}, \quad L = \frac{k_u C}{\bar I}\)

Variables

Symbol Meaning SI unit
\(C\) Battery capacity C
\(k_u\) Usable share (self-discharge, cut-off and temperature) -
\(I_a\) Current while active A
\(t_a\) Active time per wake-up s
\(I_s\) Current while asleep A
\(T\) Time between wake-ups s
\(\bar I\) Average current A
\(t_a/T\) Active share of time -
\(L\) Battery life s
\(L_y\) Battery life in years -
\(s\) Share of charge used while asleep -

Method and standards

Battery life.

Where it is used

  • Wireless sensors and meters.
  • Data loggers and remote alarms.

Common mistakes

  • Ignoring the sleep current.
  • Using the full nominal capacity in the cold.

Assumptions and limits

  • Constant currents in each state; no pulse-capacity effects.

References

  • Time-weighted average current

Questions and answers

How long will 2,400 mAh last at 25 mA for 0.5 s every 5 minutes?

With 8 µA sleep, the average is about 50 µA, so about 4 years at 80 % usable capacity.

Why does sleep current matter so much?

The device sleeps more than 99 % of the time, so even microamps add up.

What do the defaults represent?

An illustrative sensor on a 2,400 mAh battery, awake 0.5 s at 25 mA every 5 minutes and 8 µA asleep.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.