Worked example
Example: Illustrative sensor on 2400 mAh. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Battery capacity | 2,400.0 mAh |
| Usable share (self-discharge, cut-off and temperature) | 80.000 % |
| Current while active | 25.000 mA |
| Active time per wake-up | 0.50000 s |
| Current while asleep | 0.008000 mA |
| Time between wake-ups | 300.00 s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Average current | 0.049653 mA |
| Active share of time | 0.16667 % |
| Battery life | 1,611.2 d |
| Battery life in years | 4.4111 |
| Share of charge used while asleep | 16.085 % |
Open this example in the calculator and change any input.
Formula
\(\bar I = \frac{I_a t_a + I_s (T - t_a)}{T}, \quad L = \frac{k_u C}{\bar I}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Battery capacity | C |
| \(k_u\) | Usable share (self-discharge, cut-off and temperature) | - |
| \(I_a\) | Current while active | A |
| \(t_a\) | Active time per wake-up | s |
| \(I_s\) | Current while asleep | A |
| \(T\) | Time between wake-ups | s |
| \(\bar I\) | Average current | A |
| \(t_a/T\) | Active share of time | - |
| \(L\) | Battery life | s |
| \(L_y\) | Battery life in years | - |
| \(s\) | Share of charge used while asleep | - |
Method and standards
Battery life.
Where it is used
- Wireless sensors and meters.
- Data loggers and remote alarms.
Common mistakes
- Ignoring the sleep current.
- Using the full nominal capacity in the cold.
Assumptions and limits
- Constant currents in each state; no pulse-capacity effects.
References
- Time-weighted average current
Questions and answers
How long will 2,400 mAh last at 25 mA for 0.5 s every 5 minutes?
With 8 µA sleep, the average is about 50 µA, so about 4 years at 80 % usable capacity.
Why does sleep current matter so much?
The device sleeps more than 99 % of the time, so even microamps add up.
What do the defaults represent?
An illustrative sensor on a 2,400 mAh battery, awake 0.5 s at 25 mA every 5 minutes and 8 µA asleep.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.