Worked example
Example: Illustrative: 12 pF crystal, 3 pF strays, two 18 pF capacitors. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Specified load capacitance of the crystal | 12.000 pF |
| Stray capacitance (pins and PCB, 2–5 pF) | 3.0000 pF |
| Chosen capacitor C₁ (0 to use the ideal value) | 18.000 pF |
| Chosen capacitor C₂ | 18.000 pF |
| Crystal shunt capacitance | 3.0000 pF |
| Crystal motional capacitance | 0.005000 pF |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ideal equal load capacitors 2(C_L − C_stray) | 18.000 pF |
| Load capacitance with the chosen capacitors | 12.000 pF |
| Frequency error with the chosen capacitors (ppm) | 0 |
| Pulling sensitivity at C_L (ppm/pF) | -11.111 |
Open this example in the calculator and change any input.
Formula
\(C_1 = C_2 = 2(C_L - C_{stray}), \quad C_{L,actual} = \frac{C_1C_2}{C_1 + C_2} + C_{stray}, \quad \frac{\Delta f}{f} = \frac{C_m}{2}\left[\frac{1}{C_0 + C_{L,actual}} - \frac{1}{C_0 + C_L}\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_L\) | Specified load capacitance of the crystal | F |
| \(C_{stray}\) | Stray capacitance (pins and PCB, 2–5 pF) | F |
| \(C_1\) | Chosen capacitor C₁ (0 to use the ideal value) | F |
| \(C_2\) | Chosen capacitor C₂ | F |
| \(C_0\) | Crystal shunt capacitance | F |
| \(C_m\) | Crystal motional capacitance | F |
| \(C_{1} = C_{2}\) | Ideal equal load capacitors 2(C_L − C_stray) | F |
| \(C_{L,actual}\) | Load capacitance with the chosen capacitors | F |
| \(\Delta f/f\) | Frequency error with the chosen capacitors (ppm) | - |
| \(S\) | Pulling sensitivity at C_L (ppm/pF) | - |
Method and standards
Crystal load capacitance and pulling.
Where it is used
- Microcontroller and RTC clock circuits.
- Radio reference oscillators and timing.
Common mistakes
- Using C_L itself as each capacitor.
- Forgetting the PCB and pin capacitance.
Assumptions and limits
- Fundamental-mode Pierce oscillator; small pulling.
References
- Pierce oscillator load capacitance and crystal pulling
Questions and answers
Why are the capacitors twice the load capacitance?
C₁ and C₂ appear in series across the crystal, so two equal capacitors give half their value, plus the strays.
How accurate must they be?
Typical pulling is 10–20 ppm per pF; with 5 % capacitors the error is usually a few ppm, smaller than the crystal's own tolerance.